Schneider Electric

Schneider Electric LC1K0601D7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NC aux., 42VAC coil

(No reviews yet) Write a Review
SKU:
LC1K0601D7
MPN:
LC1K0601D7
Condition:
New
Mounting Support:
plate || rail
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Range:
TeSys
Utilisation Category:
AC-3 || AC-3e || AC-4
Eu Rohs Directive:
Compliant
Ambient Air Temperature For Storage:
-50-80°C
Country of Origin:
France
Product Or Component Type:
contactor
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Minimum Switching Current:
5 mA for Signaling circuit
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Auxiliary Contact Composition:
1 NC
Pole Contact Composition:
3 NO
[Ie] Rated Operational Current:
6 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 6 A (at <60°C) at <= 440 V AC AC-3e for power circuit
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
Motor Power Kw:
1.5 kW 220...230 V AC 50/60 Hz AC-3 || 2.2 kW 380...415 V AC 50/60 Hz AC-3 || 3 kW 440/690 V AC 50/60 Hz AC-3 || 1.5 kW 220...230 V AC 50/60 Hz AC-3e || 2.2 kW 380...415 V AC 50/60 Hz AC-3e || 3 kW 440/690 V AC 50/60 Hz AC-3e || 1.5 kW 220...230 V AC
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Depth:
57 mm
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Toxic Heavy Metal Free:
Yes
Minimum Switching Voltage:
17 V for Signaling circuit
Environmental Disclosure:
ENVPEP1503003EN
Sustainable Packaging:
Yes
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
[Uc] Control Circuit Voltage:
42 V AC 50/60 Hz
Operating Altitude:
6561.68 ft (2000 m) without derating
Contactor Application:
motor control
Rohs Exemption Information:
Yes
Warranty:
18 months
Electrical Durability:
1.3 Mcycles 6 A AC-3 <= 440 V || 1.3 Mcycles 6 A AC-3e <= 440 V || 0.05 Mcycles 36 A AC-4 <= 440 V
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Non Overlap Distance:
0.5 mm
Circularity Profile:
ENVEOLI1503003EN
Insulation Resistance:
> 10 MOhm for Signaling circuit
Device Short Name:
LC1K
Signaling Circuit Frequency:
<= 400 Hz
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Overvoltage Category:
III
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Reach Regulation:
Free of Substances of Very High Concern above the threshold
$57.00