Schneider Electric

Schneider Electric LC1K09008F7 Contactor, TeSys K, 4P, 2 NO + 2 NC, AC-1, lt or eq to 440V 10A, 110VAC coil

(No reviews yet) Write a Review
SKU:
LC1K09008F7
MPN:
LC1K09008F7
Condition:
New
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Range:
TeSys
Warranty:
18 months
Environmental Disclosure:
ENVPEP1503003EN
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Reach Free Of Svhc:
Yes
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Overvoltage Category:
III
Country of Origin:
Indonesia
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Poles Description:
4P
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Contactor Application:
resistive load
Mechanical Durability:
10 Mcycles
Heat Dissipation:
1.3-1.3 W
Maximum Operating Rate:
3600 cyc/h
Ambient Air Temperature For Storage:
-50-80°C
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
Signaling Circuit Frequency:
<= 400 Hz
Operating Altitude:
6561.68 ft (2000 m) without derating
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Weight:
0.18 kg
Operating Time:
10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Product Or Component Type:
contactor
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947
Rohs Exemption Information:
Yes
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
Mechanical Robustness:
shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Sustainable Offer Status:
Green Premium product
Device Application:
control
Protective Treatment:
TC IEC 60068 || TC DIN 50016
[Uc] Control Circuit Voltage:
110 V AC 50/60 Hz
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Depth:
57 mm
Eu Rohs Directive:
Compliant
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Sustainable Packaging:
Yes
Device Short Name:
LC1K
Circularity Profile:
ENVEOLI1503003EN
Width:
45 mm
Toxic Heavy Metal Free:
Yes
Net Weight:
0.18 kg
$81.00

Description

TeSys K contactor, 4 poles (2NO+2NC), for non-inductive load control applications up to 20A/690V AC-1. It provides a 110V 50/60Hz AC coil, without built-in auxiliary contact, connection by screw clamp terminals. For operating rates until 600 cycles/hour and environments until 50°C, it procures reliability and durability to standard applications. Very compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose