- [Ie] Rated Operational Current:
- 9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
- Minimum Switching Current:
- 5 mA for Signaling circuit
- Contactor Application:
- motor control || resistive load
- Warranty:
- 18 months
- Sustainable Offer Status:
- Green Premium product
- Standards:
- EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
- Safety Reliability Level:
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
- Operating Time:
- 10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing
- Reach Free Of Svhc:
- Yes
- Width:
- 45 mm
- Product Certifications:
- CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
- Auxiliary Contact Composition:
- 1 NC
- Insulation Resistance:
- > 10 MOhm for Signaling circuit
- Minimum Switching Voltage:
- 17 V for Signaling circuit
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV
- Poles Description:
- 3P
- Rated Breaking Capacity:
- 110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
- Depth:
- 57 mm
- Mercury Free:
- Yes
- Toxic Heavy Metal Free:
- Yes
- Product Or Component Type:
- contactor
- Circularity Profile:
- ENVEOLI1503003EN
- Hold-In Power Consumption In Va:
- 4.5-4.5 VA (at 20°C)
- Pole Contact Composition:
- 3 NO
- [Icw] Rated Short-Time Withstand Current:
- 90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
- Reach Regulation:
- Free of Substances of Very High Concern above the threshold
- Mechanical Durability:
- 10 Mcycles
- Heat Dissipation:
- 1.3-1.3 W
- Utilisation Category:
- AC-3 || AC-3e || AC-1 || AC-4
- Signaling Circuit Frequency:
- <= 400 Hz
- Flame Retardance:
- V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
- Inrush Power In Va:
- 30-30 VA (at 20°C)
- Electrical Durability:
- 1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
- [Ith] Conventional Free Air Thermal Current:
- 20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
- Rohs Exemption Information:
- Yes
- Connections - Terminals:
- screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
- Country of Origin:
- France
- Range:
- TeSys
- Mechanical Robustness:
- shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 || shocks contactor opened, on X axis6 Gn for 11
- Protective Treatment:
- TC IEC 60068 || TC DIN 50016
- Operating Altitude:
- 6561.68 ft (2000 m) without derating
- Sustainable Packaging:
- Yes
- Overvoltage Category:
- III
- Device Application:
- control
- Eu Rohs Directive:
- Compliant
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Auxiliary Contacts Type:
- instantaneous 1 NC