Schneider Electric

Schneider Electric LC1K0910U7 Contactor, TeSys K, 3P, AC-3, lt or eq to 440V 9A, 1 NO aux., 230 to 240VAC coil

(No reviews yet) Write a Review
SKU:
LC1K0910U7
MPN:
LC1K0910U7
Condition:
New
Auxiliary Contact Composition:
1 NO
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Motor Power Kw:
2.2 kW 220...230 V AC 50/60 Hz AC-3 || 4 kW 380...415 V AC 50/60 Hz AC-3 || 4 kW 440/690 V AC 50/60 Hz AC-3 || 2.2 kW 220...230 V AC 50/60 Hz AC-3e || 4 kW 380...415 V AC 50/60 Hz AC-3e || 4 kW 440/690 V AC 50/60 Hz AC-3e || 2.2 kW 220...230 V AC 50/
Inrush Power In Va:
30-30 VA (at 20°C)
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Control Circuit Type:
AC 50/60 Hz
Pole Contact Composition:
3 NO
Heat Dissipation:
1.3-1.3 W
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Product Or Component Type:
contactor
Mechanical Durability:
10 Mcycles
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Poles Description:
3P
Eu Rohs Directive:
Compliant
Rohs Exemption Information:
Yes
Electrical Durability:
1.3 Mcycles 9 A AC-3 <= 440 V || 1.3 Mcycles 9 A AC-3e <= 440 V || 0.16 Mcycles 20 A AC-1 <= 690 V || 0.02 Mcycles 54 A AC-4 <= 440 V
Depth:
57 mm
Country of Origin:
Singapore
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit || 10 A gG for Signaling circuit conforming to IEC 60947 || 10 A gG for Signaling circuit conforming to VDE 0660
Protective Treatment:
TC IEC 60068 || TC DIN 50016
Irms Rated Making Capacity:
110 A AC for power circuit conforming to IEC 60947 || 110 A AC for Signaling circuit conforming to IEC 60947
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
[Ie] Rated Operational Current:
9 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 9 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Minimum Switching Voltage:
17 V for Signaling circuit
Auxiliary Contacts Type:
instantaneous 1 NO
Device Application:
control
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Range:
TeSys
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || IEC 60335-1:Clause 30.2 || IEC 60335-2-40:Annex JJ || UL 60335-2-40:Annex JJ
[Ue] Rated Operational Voltage:
power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Warranty:
18 months
Reach Free Of Svhc:
Yes
[Uc] Control Circuit Voltage:
230...240 V AC 50/60 Hz
Utilisation Category:
AC-3 || AC-3e || AC-1 || AC-4
Sustainable Packaging:
Yes
Minimum Switching Current:
5 mA for Signaling circuit
Contactor Application:
resistive load || motor control
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit || 10 A (at 50°C) for Signaling circuit
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Insulation Resistance:
> 10 MOhm for Signaling circuit
$75.00

Description

LC1K0910U7 is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 240V 50/60Hz AC coil and 1NO auxiliary contact. LC1K0910U7 is a 3-pole TeSys K contactor from Schneider Electric for simple motor applications rated up to 4kW@400V. Very compact, DIN-rail compatible, with connections by screw clamp terminals, it includes a 240V 50/60Hz AC coil and 1NO built-in auxiliary contact. Available worldwide, it complies with multi-standards (IEC, UL, CSA, CCC, EAC, Marine) and is certified Green Premium (RoHs/Reach). Very compact, 45mm wide, for DIN-rail and panel mounting. Provides a control circuit compatible with 50Hz and 60Hz supplies and 1NO built-in auxiliary contact. Optimized for simple power applications. Can be completed with auxiliary contact blocks (LA1K, LA2K) and thermal relays (LR2K).
View AllClose