Schneider Electric

Schneider Electric LC2K09004E7 Changeover contactor, TeSys K, 4P, AC-1, lt or eq to 440V 10A, 48VAC coil

(No reviews yet) Write a Review
SKU:
LC2K09004E7
MPN:
LC2K09004E7
Condition:
New
Standards:
EN/IEC 60947-4-1 || GB/T 14048.4 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1
Overvoltage Category:
III
Depth:
57 mm
Toxic Heavy Metal Free:
Yes
[Ie] Rated Operational Current:
20 A (at <60°C) at <= 440 V AC AC-1 for power circuit
Operating Altitude:
6561.68 ft (2000 m) without derating
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Pole Contact Composition:
4 NO
Country of Origin:
France
Ip Degree Of Protection:
IP20 VDE 0106
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || power circuit 600 V CSA C22.2 No 14
Net Weight:
0.38 kg
Hold-In Power Consumption In Va:
4.5-4.5 VA (at 20°C)
Rohs Exemption Information:
Yes
Associated Fuse Rating:
25 A gG at <= 440 V for power circuit || 25 A aM for power circuit
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Device Short Name:
LC2K
Mercury Free:
Yes
Eu Rohs Directive:
Compliant
Electrical Durability:
0.16 Mcycles 20 A AC-1 <= 690 V
Weight:
0.38 kg
Warranty:
18 months
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Heat Dissipation:
1.3-1.3 W
Reach Free Of Svhc:
Yes
Operating Time:
10...20 ms coil energisation and NO closing || 10...20 ms coil de-energisation and NO opening
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Control Circuit Voltage Limits:
operational: 0.8...1.15 Uc (at <50°C) || drop-out: 0.2...0.75 Uc (at <50°C)
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Poles Description:
4P
Circularity Profile:
ENVEOLI1503003EN
Rated Breaking Capacity:
110 A at 220...230 V conforming to IEC 60947 || 110 A at 380...400 V conforming to IEC 60947 || 110 A at 415 V conforming to IEC 60947 || 110 A at 440 V conforming to IEC 60947 || 80 A at 500 V conforming to IEC 60947 || 70 A at 660...690 V conformin
Sustainable Offer Status:
Green Premium product
[Uc] Control Circuit Voltage:
48 V AC 50/60 Hz
Range:
TeSys
[Ue] Rated Operational Voltage:
power circuit 690 V AC 50/60 Hz
Product Or Component Type:
changeover contactor
Control Circuit Type:
AC 50/60 Hz
Environmental Disclosure:
ENVPEP1503003EN
Ambient Air Temperature For Operation:
-25-50°C
[Icw] Rated Short-Time Withstand Current:
90 A 50°C - 1 s for power circuit || 85 A 50°C - 5 s for power circuit || 80 A 50°C - 10 s for power circuit || 60 A 50°C - 30 s for power circuit || 45 A 50°C - 1 min for power circuit || 40 A 50°C - 3 min for power circuit || 20 A 50°C - >= 15 min
Contactor Application:
resistive load
[Ith] Conventional Free Air Thermal Current:
20 A (at 60°C) for power circuit
Mounting Support:
plate || rail
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
$167.00