Schneider Electric

Schneider Electric LGA36400U44X Circuit breaker, PowerPacT L, 400A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 6.3A, 80%, ABC

(No reviews yet) Write a Review
SKU:
LGA36400U44X
MPN:
LGA36400U44X
Condition:
New
Trip Unit Name:
MicroLogic 6.3 A
Circuit Breaker Application:
HACR rated
Product Or Component Type:
circuit breaker
Net Weight:
6.2 kg
Awg Gauge:
AWG 3/0...500 kcmil aluminium/copper
Color:
Black
Control Type:
toggle
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Mounting Height:
6 in
Line Rated Current:
400-400 A
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Network Frequency:
50/60 Hz
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Range:
PowerPact
Terminal Identifier:
AL600LF52K3
Depth:
110 mm
Height:
6 in
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Ambient Air Temperature For Storage:
-50-85°C
Environmental Disclosure:
ENVPEP2206029EN
Breaking Capacity Code:
G
Length:
31 mm
Warranty:
18 months
Height:
340 mm
Electrical Connection:
I-Line connection, line || lugs, load
Tightening Torque:
50-50 N.m 95-240 mm² (AWG 3/0...500 kcmil)
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Utilisation Category:
category A
Product Name:
PowerPact L
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Country of Origin:
United States
Pollution Degree:
3 IEC 60947-1
Protection Technology:
current limiter
Continuous Current Rating:
0.8
Device Application:
distribution
Ip Degree Of Protection:
front cover IP40
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Communication Interface:
Modbus || Ethernet
Pvc Free:
Yes
Breaking Capacity:
65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
Eu Rohs Directive:
Compliant with Exemptions
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.3 A, LSIG
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Rohs Exemption Information:
Yes
Device Short Name:
L-Frame
Mounting Mode:
I-Line bracket)
$8,873.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker provides MicroLogic Ammeter with a 6.3A trip unit and an LSIG function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose