PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 400A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker provides MicroLogic Ammeter with a 6.3A trip unit and an LSIG function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Trip Unit Name:
- MicroLogic 6.3 A
- Circuit Breaker Application:
- HACR rated
- Product Or Component Type:
- circuit breaker
- Net Weight:
- 6.2 kg
- Awg Gauge:
- AWG 3/0...500 kcmil aluminium/copper
- Color:
- Black
- Control Type:
- toggle
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Mounting Height:
- 6 in
- Line Rated Current:
- 400-400 A
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Network Frequency:
- 50/60 Hz
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Range:
- PowerPact
- Terminal Identifier:
- AL600LF52K3
- Depth:
- 110 mm
- Height:
- 6 in
- Local Signaling:
- ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Ambient Air Temperature For Storage:
- -50-85°C
- Environmental Disclosure:
- ENVPEP2206029EN
- Breaking Capacity Code:
- G
- Length:
- 31 mm
- Warranty:
- 18 months
- Height:
- 340 mm
- Electrical Connection:
- I-Line connection, line || lugs, load
- Tightening Torque:
- 50-50 N.m 95-240 mm² (AWG 3/0...500 kcmil)
- Mercury Free:
- Yes
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Utilisation Category:
- category A
- Product Name:
- PowerPact L
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Country of Origin:
- United States
- Pollution Degree:
- 3 IEC 60947-1
- Protection Technology:
- current limiter
- Continuous Current Rating:
- 0.8
- Device Application:
- distribution
- Ip Degree Of Protection:
- front cover IP40
- Long Time Pick-Up Adjustment Range:
- 0.25...1 x In
- Communication Interface:
- Modbus || Ethernet
- Pvc Free:
- Yes
- Breaking Capacity:
- 65 kA 240 V AC 50/60 Hz UL 489 || 35 kA 480 V AC 50/60 Hz UL 489 || 18 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489 || 20 kA 500 V DC UL 489
- Eu Rohs Directive:
- Compliant with Exemptions
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 6.3 A, LSIG
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 5000 m with derating
- Rohs Exemption Information:
- Yes
- Device Short Name:
- L-Frame
- Mounting Mode:
- I-Line bracket)