Schneider Electric

Schneider Electric LJA36600U54X Circuit breaker, PowerPacT L, 600A, 3 pole, 600VAC, 25kA, I-Line, MicroLogic 6.3E, 80%, ABC

(No reviews yet) Write a Review
SKU:
LJA36600U54X
MPN:
LJA36600U54X
Condition:
New
Mounting Support:
bracket
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Rohs Exemption Information:
Yes
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP2206029EN
Breaking Capacity:
100 kA 240 V AC 50/60 Hz UL 489 || 65 kA 480 V AC 50/60 Hz UL 489 || 25 kA 600 V AC 50/60 Hz UL 489 || 20 kA 250 V DC UL 489
Continuous Current Rating:
0.8
Height:
6 in
Control Type:
toggle
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Mounting Height:
6 in
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Pvc Free:
Yes
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Operation:
-25-70°C
Long Time Pick-Up Adjustment Range:
0.25...1 x In
Tightening Torque:
50-50 N.m 70-240 mm² (2 x AWG 2/0...500 kcmil)
Length:
31 mm
Product Name:
PowerPact L
Awg Gauge:
2 x AWG 2/0...500 kcmil aluminium/copper
Country of Origin:
United States
Trip Unit Name:
MicroLogic 6.3 E
Wire Stripping Length:
31 mm
Suitability For Isolation:
yes IEC 60947-2
Breaking Capacity Code:
J
Mercury Free:
Yes
Weight:
6.2 kg
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 5000 m with derating
Warranty:
18 months
Product Certifications:
UL || CSA || NOM
Device Short Name:
L-Frame
Depth:
110 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz IEC 60947-3
Color:
Black
Line Rated Current:
600-600 A
Ambient Air Temperature For Storage:
-50-85°C
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile:
ENVEOLI2206029EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Phase Connection:
ABC
Trip Unit Technology:
electronic, energy, MicroLogic 6.3 E, LSIG
Local Signaling:
ready 1 LED green) || alarm 1 LED 90 % Ir orange) || alarm LED 105 % Ir red) || switched off (OFF) 1 trip indicator green)
Device Application:
distribution
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Range:
PowerPact
Eu Rohs Directive:
Compliant with Exemptions
Pollution Degree:
3 IEC 60947-1
$15,329.00

Description

PowerPacT L-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT L-Frame circuit breakers are available with electronic trip units. All PowerPacT L-Frame circuit breakers are equipped with dual-break rotating contacts that reduce the amount of peak current during a short circuit fault. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT L circuit breakers are available in 3 and 4-pole unit mount, I-Line, and drawout constructions. This PowerPacT L, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker provides MicroLogic Energy with a 6.3E trip unit and an LSIG function. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT L circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose