power circuit <= 690 V AC <= 400 Hz || Signaling circuit <= 690 V AC <= 400 Hz
Hold-In Power Consumption In W:
1.8-1.8 W 20°C
Mechanical Durability:
30 Mcycles
Range:
TeSys
Device Short Name:
LP4K
Motor Power Kw:
3 kW 220...230 V AC 50/60 Hz AC-3 || 5.5 kW 380...415 V AC 50/60 Hz AC-3 || 5.5 kW 440 V AC 50/60 Hz AC-3 || 4 kW 690 V AC 50/60 Hz AC-3 || 3 kW 220...230 V AC 50/60 Hz AC-3e || 5.5 kW 380...415 V AC 50/60 Hz AC-3e || 5.5 kW 440 V AC 50/60 Hz AC-3e |
Contactor Application:
resistive load || motor control
[Uimp] Rated Impulse Withstand Voltage:
8 kV
Operating Time:
10...20 ms coil de-energisation and NO opening || 30...40 ms coil energisation and NO closing
[Ie] Rated Operational Current:
12 A (at <60°C) at <= 440 V AC AC-3 for power circuit || 12 A (at <60°C) at <= 440 V AC AC-3e for power circuit || 20 A (at <60°C) at <= 690 V AC AC-1 for power circuit
Width:
45 mm
Tightening Torque:
0.8-1.3 N.m screw clamp terminals Philips No 2 || 0.8-1.3 N.m screw clamp terminals flat Ø 6 mm || 0.8-1.3 N.m screw clamp terminals pozidriv No 2
Net Weight:
0.235 kg
Environmental Disclosure:
ENVPEP1503003EN
[Ui] Rated Insulation Voltage:
power circuit 600 V UL 508 || power circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-4-1 || Signaling circuit 690 V IEC 60947-5-1 || Signaling circuit 600 V UL 508 || power circuit 600 V CSA C22.2 No 14 || Signaling circuit 600 V CSA
Connections - Terminals:
screw clamp terminals 1 1.5-4 mm²solid || screw clamp terminals 1 0.75-4 mm²flexible without cable end || screw clamp terminals 1 0.34-2.5 mm²flexible with cable end || screw clamp terminals 2 1.5-4 mm²solid || screw clamp terminals 2 0.75-4
Average Impedance:
3 mOhm - Ith 20 A 50 Hz for power circuit
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Mercury Free:
Yes
Product Certifications:
CB Scheme || CCC || UL || CSA || EAC || CE || UKCA
Minimum Switching Voltage:
17 V for Signaling circuit
Maximum Operating Rate:
3600 cyc/h
Inrush Power In W:
1.8-1.8 W 20°C)
Country of Origin:
France
Rohs Exemption Information:
Yes
Operating Altitude:
6561.68 ft (2000 m) without derating
Weight:
0.235 kg
Depth:
57 mm
[Icw] Rated Short-Time Withstand Current:
115 A 50°C - 1 s for power circuit || 105 A 50°C - 5 s for power circuit || 100 A 50°C - 10 s for power circuit || 75 A 50°C - 30 s for power circuit || 55 A 50°C - 1 min for power circuit || 50 A 50°C - 3 min for power circuit || 25 A 50°C - >= 15 m
LP1K0610ED is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 48 V DC coil and 1NO auxiliary contact allowing easy integration...
LP1K0910ED is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 48 V DC coil and 1NO auxiliary contact allowing easy integration...
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 12V DC coil, 1NO...
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V DC coil with...
LP1K12103BD3 from Schneider Electric is a 3-pole TeSys K contactor for motor applications up to 5.5kW@400V. It provides a 24V DC coil with surge suppressor, 1NO built-in auxiliary contact, connection...
TeSys K contactor, 3 poles (3NO), for motor control applications up to 12A/690V AC-3 (5.5kW@400V), and for non-inductive load control applications up to 20A/690V AC-1. It provides a 24V DC coil, 1NO...
LP1K1210BD is a compact 3-pole TeSys K contactor from Schneider Electric for motor applications. Rated 9A AC-3 4kW@400V, it includes a 24V DC coil and 1NO auxiliary contact allowing easy integration...