Schneider Electric LTMR100DFM Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 5 to 100A, 100 to 240VAC
Schneider Electric
$850.00
TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. DeviceNet protocol is used by this controller. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 5 to 100 amperes. 120 to 240 VAC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.
- Maximum Operating Frequency:
- 2 Hz
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Tightening Torque:
- control circuit 0.5-0.6 N.m flat 3 mm
- Overvoltage Category:
- III
- Rohs Exemption Information:
- Yes
- Country of Origin:
- Singapore
- Fire Resistance:
- 650°C EN/IEC 60695-2-12 || 960°C UL 94
- Mechanical Robustness:
- vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 || vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 || shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Contacts Type And Composition:
- 1 NO + 1 NC fault signal || 3 NO
- Warranty:
- 18 months
- Sustainable Offer Status:
- Green Premium product
- Connection Pitch:
- 5.08 mm
- Device Short Name:
- LTMR
- Standards:
- EN 60947-4-1 || UL 508 || IEC 60947-4-1 || CSA C22.2 No 14 || IACS E10
- Electromagnetic Compatibility:
- electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 || relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 ||
- Depth:
- 122.5 mm
- Product Certifications:
- CSA || DNV || LROS (Lloyds register of shipping) || RINA || EAC || GL || UL || ATEX || BV || CCC || RMRoS || KERI || ABS || NOM || C-tick
- Metering Type:
- imbalance current || temperature || average current Iavg || earth-fault current || phase current I1, I2, I3 RMS
- Protective Treatment:
- 12 x 24 hour cycles EN/IEC 60068-2-30 || 48 h EN/IEC 60070-2-11 || TH EN/IEC 60068
- Associated Fuse Rating:
- 4 A gG output || 0.5 A gG control circuit
- Maximum Operating Rate:
- 1800 cyc/h
- Current Consumption:
- 8...62.8 mA
- Measurement Accuracy:
- 5...15 % earth fault current internal measurement || 1 % voltage 100...830 V) || 3 % power factor || 5 % earth fault current external measurement || +/- 30 min/year internal clock || 0,02 Temperature || 5 % active and reactive power || 0,02 current
- Load Current:
- 5 A 250 V AC logic output || 5 A 30 V DC logic output
- Ambient Air Temperature For Storage:
- -40-80°C
- Web Services:
- web server
- Device Application:
- equipment monitoring and control
- Circularity Profile:
- ENVEOLI100411EN_V2
- Net Weight:
- 0.53 kg
- Environmental Disclosure:
- ENVPEP060308EN_V2
- Mercury Free:
- Yes
- Supply Voltage Limits:
- 93.5-264 V AC
- Height:
- 61 mm
- Communication Port Protocol:
- DeviceNet
- Compatibility Code:
- LTMR
- Connections - Terminals:
- control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible with cable end || control circuit connector 1 0.2-2.5 mm² AWG 24...AWG 14)flexible without cable end || control circuit connector 1 0.25-2.5 mm² AWG 24...AWG 14)flexible without cab
- Pvc Free:
- Yes
- Ambient Air Temperature For Operation:
- -20-60°C
- Product Or Component Type:
- motor controller
- Protection Type:
- phase failure || overload (long time) || load fluctuation || thermal overload protection || power factor variation || overload || locked rotor || thermal protection || earth-leakage protection || phase unbalance || reverse polarity protection
- Permissible Power:
- 480 VA AC-15), Ie = 2 A, 500000 cycles output) || 30 W DC-13), Ie = 1.25 A, 500000 cycles output)
- Halogen Content Performance:
- Halogen free plastic parts product
- Input Current:
- 3.1 mA 100 V || 7.5 mA 240 V
- Operating Altitude:
- <= 6561.68 ft (2000 m) without derating
- Current State 0 Guaranteed:
- logic input 0...40 V <= 15 mA 25 ms
- Pollution Degree:
- 3
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.