Schneider Electric LUCBX6FU Advanced Con 0.15-0.6A 110-240
Schneider Electric
$150.00
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 0.09kW@400V. It provides full protection to motors with a rated current Ir 0.15-0.6A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 110-240V AC / 110-220V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
- Fire Resistance:
- 960 °C parts supporting live components IEC 60695-2-12 || 650 °C IEC 60695-2-12
- Ambient Air Temperature For Operation:
- -25-70 °C
- Vibration Resistance:
- 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
- Motor Power Kw:
- 0.09 kW 400...440 V AC 50/60 Hz
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Uimp] Rated Impulse Withstand Voltage:
- 6 kV IEC 60947-6-2
- Standards:
- EN 60947-6-2 || IEC 60947-6-2 || UL 60947-4-1, with phase barrier || CSA C22.2 No 60947-4-1, with phase barrier
- Depth:
- 60 mm
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Resistance To Radiated Fields:
- 10 V/m 3 IEC 61000-4-3
- Utilisation Category:
- AC-44 || AC-43 || AC-41
- Thermal Overload Class:
- class 10 40-60 Hz -25-70 °C IEC 60947-6-2 || class 10 40-60 Hz -25-70 °C UL 508
- Heat Dissipation:
- 2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
- Product Certifications:
- CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
- Product Specific Application:
- basic protection and advanced functions, communication
- Operating Time:
- 35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 50 ms closing with LUB12 control circuit || 50 ms closing with LUB32 control circuit || 50 ms closing with LUB38 contr
- Non-Dissipating Shock Wave:
- 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
- Device Short Name:
- LUCB
- Halogen Content Performance:
- Halogen free plastic parts product
- Product Or Component Type:
- advanced control unit
- Range Of Product:
- TeSys Ultra
- [Uc] Control Circuit Voltage:
- 110...240 V AC || 110...220 V DC
- Safe Separation Of Circuit:
- 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
- Range:
- TeSys
- Height:
- 66 mm
- Fixing Mode:
- plug-in front face)
- Warranty:
- 18 months
- Thermal Protection Adjustment Range:
- 0.15-0.6 A
- Function Available:
- manual reset || protection against phase failure and phase imbalance || protection against overload and short-circuit || earth fault protection
- Operating Altitude:
- 6561.68 ft (2000 m)
- Immunity To Radioelectric Fields:
- 10 V IEC 61000-4-6
- Product Name:
- TeSys Ultra
- Phase Failure Sensitivity:
- yes
- Rohs Exemption Information:
- Yes
- Environmental Disclosure:
- ENVPEP080204EN
- Load Type:
- 3-phase motor self-cooled
- Protective Treatment:
- TH IEC 60068
- Compatibility Code:
- LUCB
- Ambient Air Temperature For Storage:
- -40-85 °C
- Tripping Threshold:
- 14.2 x Ir +/- 20 %
- Reset:
- manual reset
- [Ue] Rated Operational Voltage:
- 690 V AC
- Eu Rohs Directive:
- Compliant with Exemptions
- Control Circuit Voltage Limits:
- 88...264 V AC 110...240 V in operation || 88...242 V DC 110...220 V in operation || 55 V AC 110...240 V drop-out || 55 V DC 110...220 V drop-out
- Ip Degree Of Protection:
- IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
- Network Frequency:
- 40...60 Hz
- Circularity Profile:
- ENVEOLI100414
- Shock Resistance:
- 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
- Mercury Free:
- Yes
- Typical Current Consumption:
- 280 mA 110...240 V AC I maximum while closing with LUB12 || 280 mA 110...240 V AC I maximum while closing with LUB32 || 280 mA 110...240 V AC I maximum while closing with LUB38 || 280 mA 110...220 V DC I maximum while closing with LUB12 || 280 mA 110
- Device Application:
- motor control || motor protection
- Immunity To Microbreaks:
- 3 ms
- Immunity To Voltage Dips:
- 70 % / 500 ms IEC 61000-4-11
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Width:
- 45 mm
- Resistance To Electrostatic Discharge:
- 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
- Sustainable Offer Status:
- Green Premium product
- [Ui] Rated Insulation Voltage:
- 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
- Pvc Free:
- Yes
- Resistance To Fast Transients:
- 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
- Product Compatibility:
- power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12FU || reversing contactor breaker LU2B32FU || reversing contactor breaker LU2B38FU
- Datasheet: