Schneider Electric

Schneider Electric LX1G4SLSEA Control module,TeSys Giga,200-500V AC/DC,for LC1G400-500/4P advanced version

(No reviews yet) Write a Review
SKU:
LX1G4SLSEA
MPN:
LX1G4SLSEA
Condition:
New
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Mercury Free:
Yes
Hold-In Power Consumption In Va:
14.9-14.9 VA 480 V AC, 60 Hz
[Uc] Control Circuit Voltage:
200...500 V AC/DC 50/60 Hz
Operating Altitude:
9842.52 ft (3000 m) without derating || 5000 m with derating factor
Pvc Free:
Yes
Maximum Operating Rate:
600 cyc/mn 60°C
Environmental Disclosure:
ENVPEP2105013
Ip Degree Of Protection:
IP20 IEC 60529
Standards:
EN/IEC 60947-4-1 || UL 60947-4-1A || CSA C22.2 No 60947-4-1
Inrush Power In W:
260.0 W DC
Product Compatibility:
LC1G400...500
Halogen Content Performance:
Halogen free plastic parts product
Poles Description:
4P
Electromagnetic Compatibility:
EMC immunity conforming to IEC 60947-4-1 || emission tests criteria A conforming to IEC 60947-4-1 || immunity to radiated radio-electrical interference - test level: 20 V/m conforming to EN/IEC 61000-4-3 || voltage dips and interruptions immunity tes
Product Or Component Type:
contactor coil
Country of Origin:
China
Hold-In Power Consumption In W:
4.8-4.8 W DC
Device Short Name:
LX1G
China Rohs Regulation:
X
Ambient Air Temperature For Operation:
-25-60°C
Ambient Air Temperature For Storage:
-60-80°C
Connections - Terminals:
control circuit push-in termination 1 0.2-2.5 mm² solid stranded without cable end sleeve AWG 26...AWG 12 || control circuit push-in termination 1 0.25-2.5 mm² flexible with cable end sleeve AWG 24...AWG 14 || control circuit push-in termination 2
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For m
Coil Technology:
built-in bidirectional peak limiting
Permissible Ambient Air Temperature Around The Device:
-40-70°C at Uc
Rohs Exemption Information:
Yes
Range Compatibility:
TeSys G LX1G contactor coil
Inrush Power In Va:
400-400 VA 480 V AC, 60 Hz
Circularity Profile:
ENVEOLI2105013
Sustainable Offer Status:
Green Premium product
Operating Time:
20...35 ms opening || 40...55 ms closing
Quantity Per Set:
1
Depth:
93.0 mm
Range:
TeSys
Control Circuit Voltage Limits:
operational 0.8...1.1 Uc 60°C) || drop-out 0...0.45 Uc 60°C)
Mechanical Durability:
5 Mcycles
Pollution Degree:
3 IEC 60947-1
$285.00

Description

It is a 200-500V AC/DC control module for 4 poles TeSys Giga 400-500 contactor (advanced version). Coil designed for less energy consumption and wider voltage band-width, connection by spring terminal. It allows contactor operation with high AC-3 operating rates until 600 cycles/hour and environments until 60°C. Control module has connectors for connecting the coil control A1, A2 circuit & PLC output control, pole status and diagnostic signaling circuits. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It is accessible from the front and maintained with very low down times. Unique QR code provides quick access to complete product data.
View AllClose