PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has the adjustable amperage option, allowing trip setting changes between 300A to 800A using a selector switch. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT M, 300A to 800A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Ambient Air Temperature For Operation:
- -25-70 °C
- Height:
- 12.86 in
- Trip Unit Name:
- ET 1.0
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Wire Stripping Length:
- 25 mm
- Pvc Free:
- Yes
- Control Type:
- operating handle
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Communication Interface:
- Modbus
- Poles Description:
- 3P
- Ip Degree Of Protection:
- IP40
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Device Application:
- distribution
- Terminal Identifier:
- AL800M23K
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Depth:
- 8.05 in
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Pollution Degree:
- 3 IEC 60947-1
- Breaking Capacity Code:
- G
- Product Name:
- PowerPact M
- Eu Rohs Directive:
- Compliant with Exemptions
- Sustainable Offer Status:
- Green Premium product
- Line Rated Current:
- 300-800 A
- Suitability For Isolation:
- yes IEC 60947-2
- Mercury Free:
- Yes
- Product Certifications:
- UL || CSA || NOM
- Mounting Height:
- 9 in
- Quantity Per Set:
- 1
- Mounting Mode:
- I-Line bracket)
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Electrical Connection:
- I-Line connection, line || lugs, load
- Awg Gauge:
- 3 x AWG 3/0...3 x 500 kcmil aluminium/copper
- Long Time Pick-Up Adjustment Range:
- 300...800 A
- Range:
- PowerPact
- Width:
- 8.27 in
- Color:
- Black
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
- Utilisation Category:
- category A
- Accessory / Separate Part Type:
- communication module
- Trip Unit Technology:
- electronic, basic, ET 1.0,
- Product Or Component Type:
- circuit breaker
- Mounting Support:
- bracket
- Environmental Disclosure:
- ENVPEP2206030EN
- Continuous Current Rating:
- 0.8
- Magnetic Tripping Current:
- 1600-8000 A
- Rohs Exemption Information:
- Yes
- Quality Labels:
- CE
- Ambient Air Temperature For Storage:
- -50-85 °C
- Network Frequency:
- 50/60 Hz
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Net Weight:
- 29 lb(US)
- Local Signalling:
- 1 trip indicator green)
- Circuit Breaker Application:
- HACR rated
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Circularity Profile:
- ENVEOLI2206030EN
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2