- Rohs Exemption Information:
- Yes
- Breaking Capacity Code:
- G
- Mounting Support:
- lug
- Width:
- 8.27 in
- Mercury Free:
- Yes
- Ambient Air Temperature For Storage:
- -50-85 °C
- Color:
- Black
- Product Or Component Type:
- circuit breaker
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Quantity Per Set:
- 1
- Ambient Air Temperature For Operation:
- -25-70 °C
- Control Type:
- operating handle
- Environmental Disclosure:
- ENVPEP2206030EN
- Sustainable Offer Status:
- Green Premium product
- Poles Description:
- 2P
- Continuous Current Rating:
- 0.8
- Circularity Profile:
- ENVEOLI2206030EN
- Line Rated Current:
- 450-450 A
- Device Application:
- distribution
- Product Name:
- PowerPact M
- Product Certifications:
- UL || CSA || NOM
- Electrical Connection:
- lugs, load || lugs, line
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Long Time Pick-Up Adjustment Range:
- 300...800 A
- Utilisation Category:
- category A
- Height:
- 12.86 in
- Pollution Degree:
- 3 IEC 60947-1
- Eu Rohs Directive:
- Compliant with Exemptions
- Range:
- PowerPact
- Mounting Mode:
- unit mount lug)
- Wire Stripping Length:
- 25 mm
- Terminal Identifier:
- AL800M23K
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Trip Unit Name:
- ET 1.0
- Awg Gauge:
- 3 x AWG 3/0...3 x 500 kcmil aluminium/copper
- Depth:
- 8.05 in
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Circuit Breaker Application:
- HACR rated
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Network Frequency:
- 50/60 Hz
- Ip Degree Of Protection:
- IP40
- Trip Unit Technology:
- electronic, basic, ET 1.0,
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Net Weight:
- 29 lb(US)
- Magnetic Tripping Current:
- 900-4500 A
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
- Pvc Free:
- Yes
- Suitability For Isolation:
- yes IEC 60947-2
- Warranty:
- 18 months
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Local Signalling:
- 1 trip indicator green)
- Quality Labels:
- CE
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- QN-QUOTE-REQUEST:
- true