Schneider Electric MGL26450 Molded Case Circuit Breaker 600V 450A

(No reviews yet) Write a Review
SKU:
MGL26450
UPC:
785901689645
Condition:
New
Rohs Exemption Information:
Yes
Breaking Capacity Code:
G
Mounting Support:
lug
Width:
8.27 in
Mercury Free:
Yes
Ambient Air Temperature For Storage:
-50-85 °C
Color:
Black
Product Or Component Type:
circuit breaker
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Quantity Per Set:
1
Ambient Air Temperature For Operation:
-25-70 °C
Control Type:
operating handle
Environmental Disclosure:
ENVPEP2206030EN
Sustainable Offer Status:
Green Premium product
Poles Description:
2P
Continuous Current Rating:
0.8
Circularity Profile:
ENVEOLI2206030EN
Line Rated Current:
450-450 A
Device Application:
distribution
Product Name:
PowerPact M
Product Certifications:
UL || CSA || NOM
Electrical Connection:
lugs, load || lugs, line
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Long Time Pick-Up Adjustment Range:
300...800 A
Utilisation Category:
category A
Height:
12.86 in
Pollution Degree:
3 IEC 60947-1
Eu Rohs Directive:
Compliant with Exemptions
Range:
PowerPact
Mounting Mode:
unit mount lug)
Wire Stripping Length:
25 mm
Terminal Identifier:
AL800M23K
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Trip Unit Name:
ET 1.0
Awg Gauge:
3 x AWG 3/0...3 x 500 kcmil aluminium/copper
Depth:
8.05 in
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circuit Breaker Application:
HACR rated
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Network Frequency:
50/60 Hz
Ip Degree Of Protection:
IP40
Trip Unit Technology:
electronic, basic, ET 1.0,
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Net Weight:
29 lb(US)
Magnetic Tripping Current:
900-4500 A
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
Pvc Free:
Yes
Suitability For Isolation:
yes IEC 60947-2
Warranty:
18 months
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Local Signalling:
1 trip indicator green)
Quality Labels:
CE
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
$5,960.00

Description

PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has an electronic trip unit, ET 1.0. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has lugs on both the line and load sides. This PowerPacT M, 450A, 2 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose