Schneider Electric MGL36400LH Molded Case Circuit Breaker 600V 400A
Schneider Electric
$7,655.00
PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has an electronic trip unit, ET 1.0. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has lugs on both the line and load sides. This PowerPacT M, 400A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. This unit includes high amperage lugs on both ends. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Line Rated Current:
- 400-400 A
- Poles Description:
- 3P
- Awg Gauge:
- AWG 3/0...500 kcmil
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Device Application:
- distribution
- Breaking Capacity Code:
- G
- Depth:
- 8.05 in
- Trip Unit Technology:
- electronic, basic, ET 1.0,
- Eu Rohs Directive:
- Compliant with Exemptions
- Pollution Degree:
- 3 IEC 60947-1
- Environmental Disclosure:
- ENVPEP2206030EN
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Accessory / Separate Part Type:
- high amperage lug
- Height:
- 12.86 in
- Warranty:
- 18 months
- Quantity Per Set:
- 1
- Pvc Free:
- Yes
- Magnetic Tripping Current:
- 800-4000 A
- Range:
- PowerPact
- Ip Degree Of Protection:
- IP40
- Electrical Connection:
- lugs, load || lugs, line
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Quality Labels:
- CE
- Ambient Air Temperature For Operation:
- -25-70 °C
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Wire Stripping Length:
- 30 mm || 57 mm
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Mercury Free:
- Yes
- Utilisation Category:
- category A
- Product Name:
- PowerPact M
- Tightening Torque:
- 50-50 N.m 95-240 mm² (AWG 3/0...500 kcmil)
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Ambient Air Temperature For Storage:
- -50-85 °C
- Terminal Identifier:
- AL1200P25K
- Circularity Profile:
- ENVEOLI2206030EN
- Width:
- 8.27 in
- Net Weight:
- 29 lb(US)
- Suitability For Isolation:
- yes IEC 60947-2
- Local Signalling:
- 1 trip indicator green)
- Trip Unit Name:
- ET 1.0
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Long Time Pick-Up Adjustment Range:
- 300...800 A
- Continuous Current Rating:
- 0.8
- Mounting Support:
- lug
- Circuit Breaker Application:
- HACR rated
- Product Or Component Type:
- circuit breaker
- Mounting Mode:
- unit mount lug)
- Control Type:
- operating handle
- Color:
- Black
- Network Frequency:
- 50/60 Hz
- Sustainable Offer Status:
- Green Premium product
- Product Certifications:
- UL || CSA || NOM
- Rohs Exemption Information:
- Yes
- Brochure:
- View
- Catalog:
- View
- Datasheet:
- View