Schneider Electric

Schneider Electric MGL36600 Molded Case Circuit Breaker 600V 600A

(No reviews yet) Write a Review
SKU:
MGL36600
UPC:
785901420286
Condition:
New
Eu Rohs Directive:
Compliant with Exemptions
Network Frequency:
50/60 Hz
Electrical Connection:
lugs, load || lugs, line
Pvc Free:
Yes
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Environmental Disclosure:
ENVPEP2206030EN
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Magnetic Tripping Current:
1200-6000 A
Net Weight:
29 lb(US)
Sustainable Offer Status:
Green Premium product
Mounting Support:
lug
Depth:
8.05 in
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Device Application:
distribution
Breaking Capacity Code:
G
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Trip Unit Name:
ET 1.0
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Continuous Current Rating:
0.8
Circularity Profile:
ENVEOLI2206030EN
Ip Degree Of Protection:
IP40
Suitability For Isolation:
yes IEC 60947-2
Color:
Black
Utilisation Category:
category A
Poles Description:
3P
Height:
12.86 in
Line Rated Current:
600-600 A
Local Signalling:
1 trip indicator green)
Pollution Degree:
3 IEC 60947-1
Long Time Pick-Up Adjustment Range:
300...800 A
Trip Unit Technology:
electronic, basic, ET 1.0,
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Range:
PowerPact
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Product Or Component Type:
circuit breaker
Product Certifications:
UL || CSA || NOM
Warranty:
18 months
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
Awg Gauge:
3 x AWG 3/0...3 x 500 kcmil aluminium/copper
Ambient Air Temperature For Operation:
-25-70 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Quantity Per Set:
1
Product Name:
PowerPact M
Wire Stripping Length:
25 mm
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Mode:
unit mount lug)
Rohs Exemption Information:
Yes
Control Type:
operating handle
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Storage:
-50-85 °C
Width:
8.27 in
Circuit Breaker Application:
HACR rated
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Mercury Free:
Yes
Quality Labels:
CE
Terminal Identifier:
AL800M23K
Brochure:
View
Catalog:
View
Datasheet:
View
$7,560.00

Description

PowerPacT M-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT M-Frame circuit breakers have either a fixed long time electronic trip unit or an adjustable amperage version. This circuit breaker has an electronic trip unit, ET 1.0. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT M circuit breakers are available in 2 and 3-pole unit mount or I-Line construction. This unit has lugs on both the line and load sides. This PowerPacT M, 600A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT M circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose