- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Poles Description:
- 3P
- Circularity Profile:
- ENVEOLI2206030EN
- Color:
- Black
- Depth:
- 8.05 in
- Circuit Breaker Application:
- HACR rated
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Sustainable Offer Status:
- Green Premium product
- Electrical Connection:
- lugs, load || lugs, line
- Quality Labels:
- CE
- Product Or Component Type:
- circuit breaker
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
- Range:
- PowerPact
- Magnetic Tripping Current:
- 1200-6000 A
- Rohs Exemption Information:
- Yes
- Ambient Air Temperature For Storage:
- -50-85 °C
- Mercury Free:
- Yes
- Pvc Free:
- Yes
- Device Application:
- distribution
- Product Name:
- PowerPact M
- Mounting Mode:
- unit mount lug)
- Control Type:
- operating handle
- Continuous Current Rating:
- 0.8
- Product Certifications:
- UL || CSA || NOM
- Pollution Degree:
- 3 IEC 60947-1
- Utilisation Category:
- category A
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Width:
- 8.27 in
- Awg Gauge:
- 3 x AWG 3/0...3 x 500 kcmil aluminium/copper
- Net Weight:
- 29 lb(US)
- Warranty:
- 18 months
- Ambient Air Temperature For Operation:
- -25-70 °C
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...3 x 500 kcmil)
- Wire Stripping Length:
- 25 mm
- Breaking Capacity Code:
- J
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Trip Unit Technology:
- electronic, basic, ET 1.0,
- Trip Unit Name:
- ET 1.0
- Line Rated Current:
- 600-600 A
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Mounting Support:
- lug
- Accessory / Separate Part Type:
- shunt trip 24...30 V AC/DC
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Long Time Pick-Up Adjustment Range:
- 300...800 A
- Height:
- 12.86 in
- Quantity Per Set:
- 1
- Environmental Disclosure:
- ENVPEP2206030EN
- Ip Degree Of Protection:
- IP40
- Network Frequency:
- 50/60 Hz
- Suitability For Isolation:
- yes IEC 60947-2
- Terminal Identifier:
- AL800M23K
- Local Signalling:
- 1 trip indicator green)
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Eu Rohs Directive:
- Compliant with Exemptions
- QN-QUOTE-REQUEST:
- true