Schneider Electric

Schneider Electric PGA36060U41A Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 18kA, I-Line, Micrologic 3.0A, 80%, ABC

(No reviews yet) Write a Review
SKU:
PGA36060U41A
MPN:
PGA36060U41A
Condition:
New
Pvc Free:
Yes
Net Weight:
32 lb(US)
Warranty:
18 months
Local Signaling:
overload 1 1 LED amber) || 1 flag green) || trip causes 4 trip indicator red)
Ip Degree Of Protection:
front cover IP40
Product Or Component Type:
circuit breaker
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Length:
25 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Rohs Exemption Information:
Yes
Height:
9 in
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Mode:
I-Line bracket)
Range:
PowerPact
Mounting Support:
bracket
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Network Frequency:
50/60 Hz
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Poles Description:
3P
Quality Labels:
CE
Circularity Profile:
ENVEOLI2206033EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pollution Degree:
3 IEC 60947-1
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Continuous Current Rating:
0.8
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Width:
8.27 in
Wire Stripping Length:
25 mm
Weight:
32 lb(US)
Trip Unit Name:
MicroLogic 3.0 A
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Breaking Capacity Code:
G
Ambient Air Temperature For Operation:
-25-70°C
Phase Connection:
ABC
Circuit Breaker Application:
HACR rated
Height:
12.86 in
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Trip Unit Technology:
electronic, ammeter, MicroLogic 3.0 A, LI
Environmental Disclosure:
ENVPEP2206033EN
Terminal Identifier:
AL800M23K
Depth:
8.05 in
Product Name:
PowerPact P
Mounting Height:
9 in
Eu Rohs Directive:
Compliant with Exemptions
Electrical Connection:
I-Line connection, line || lugs, load
Device Application:
distribution
Sustainable Offer Status:
Green Premium product
$16,242.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 3.0A trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose