PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1200A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
- Width:
- 8.27 in
- Control Type:
- toggle
- Range:
- PowerPact
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Mounting Mode:
- I-Line bracket)
- Warranty:
- 18 months
- Device Application:
- distribution
- Trip Unit Technology:
- electronic, standard, MicroLogic 3.0, LI
- Ambient Air Temperature For Storage:
- -50-85 °C
- Product Or Component Type:
- circuit breaker
- Depth:
- 8.05 in
- Eu Rohs Directive:
- Compliant with Exemptions
- Quality Labels:
- CE
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Line Rated Current:
- 1200-1200 A
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Product Certifications:
- UL || CSA || NOM
- Phase Connection:
- ABC
- Breaking Capacity Code:
- G
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Mounting Height:
- 9 in
- Electrical Connection:
- I-Line connection, line || lugs, load
- Quantity Per Set:
- 1
- Ip Degree Of Protection:
- front cover IP40
- Environmental Disclosure:
- ENVPEP2206033EN
- Sustainable Offer Status:
- Green Premium product
- Circuit Breaker Application:
- HACR rated
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Pollution Degree:
- 3 IEC 60947-1
- Circularity Profile:
- ENVEOLI2206033EN
- Tightening Torque:
- 50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Local Signalling:
- overload 1 1 LED amber) || 1 trip indicator green)
- Rohs Exemption Information:
- Yes
- Wire Stripping Length:
- 30 mm
- Height:
- 16.16 in
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Net Weight:
- 32 lb(US)
- Terminal Identifier:
- AL1200P25K
- Mounting Support:
- bracket
- Poles Description:
- 3P
- Trip Unit Name:
- MicroLogic 3.0
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Network Frequency:
- 50/60 Hz
- Awg Gauge:
- 4 x AWG 3/0...500 kcmil aluminium/copper
- Product Name:
- PowerPact P
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Continuous Current Rating:
- 0.8
- Mercury Free:
- Yes
- Pvc Free:
- Yes
- Ambient Air Temperature For Operation:
- -2-70 °C