Schneider Electric PGF36100U31A Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PGF36100U31A
UPC:
785901616771
Condition:
New
Eu Rohs Directive:
Compliant with Exemptions
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Operation:
-2-70 °C
Device Application:
distribution
Product Name:
PowerPact P
Width:
8.27 in
Electrical Connection:
busbar connection, line || busbar connection, load
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Wire Stripping Length:
30 mm
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Depth:
8.05 in
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Warranty:
18 months
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Quality Labels:
CE
Network Frequency:
50/60 Hz
Range:
PowerPact
Poles Description:
3P
Terminal Identifier:
AL1200P25K
Control Type:
toggle
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Product Or Component Type:
circuit breaker
Trip Unit Technology:
electronic, standard, MicroLogic 3.0, LI
Pvc Free:
Yes
Breaking Capacity Code:
G
Ip Degree Of Protection:
front cover IP40
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Ambient Air Temperature For Storage:
-50-85 °C
Pollution Degree:
3 IEC 60947-1
Trip Unit Name:
MicroLogic 3.0
Quantity Per Set:
1
Continuous Current Rating:
0.8
Mounting Support:
busbar
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Rohs Exemption Information:
Yes
Environmental Disclosure:
ENVPEP2206033EN
Net Weight:
32 lb(US)
Product Certifications:
UL || CSA || NOM
Mercury Free:
Yes
Line Rated Current:
1000-1000 A
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Sustainable Offer Status:
Green Premium product
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Mounting Mode:
unit mount busbar)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Circularity Profile:
ENVEOLI2206033EN
Height:
16.16 in
$19,836.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 3.0 trip unit and an LI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has a busbar connection. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose