- Pollution Degree:
- 3 IEC 60947-1
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Quantity Per Set:
- 1
- Line Rated Current:
- 250-250 A
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Trip Unit Technology:
- electronic, standard, MicroLogic 5.0, LSI
- Product Name:
- PowerPact P
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Circularity Profile:
- ENVEOLI2206033EN
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Eu Rohs Directive:
- Compliant with Exemptions
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Ambient Air Temperature For Storage:
- -50-85 °C
- Rohs Exemption Information:
- Yes
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Ambient Air Temperature For Operation:
- -2-70 °C
- Poles Description:
- 3P
- Ip Degree Of Protection:
- front cover IP40
- Environmental Disclosure:
- ENVPEP2206033EN
- Trip Unit Name:
- MicroLogic 5.0
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Width:
- 8.27 in
- Net Weight:
- 32 lb(US)
- Range:
- PowerPact
- Mercury Free:
- Yes
- Local Signalling:
- overload 1 1 LED amber) || 1 trip indicator green)
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Electrical Connection:
- lugs, load || lugs, line
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Sustainable Offer Status:
- Green Premium product
- Product Certifications:
- UL || CSA || NOM
- Continuous Current Rating:
- 0.8
- Quality Labels:
- CE
- Circuit Breaker Application:
- HACR rated
- Terminal Identifier:
- AL800M23K
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Breaking Capacity Code:
- G
- Depth:
- 8.05 in
- Control Type:
- toggle
- Network Frequency:
- 50/60 Hz
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Height:
- 12.86 in
- Device Application:
- distribution
- Warranty:
- 18 months
- Product Or Component Type:
- circuit breaker
- Pvc Free:
- Yes
- Wire Stripping Length:
- 25 mm
- QN-QUOTE-REQUEST: