Schneider Electric PGL36060CU33A Molded Case Circuit Breaker 600V 600A

(No reviews yet) Write a Review
SKU:
PGL36060CU33A
UPC:
7.85902E+11
Condition:
New
Ambient Air Temperature For Operation:
-2-70 °C
Pollution Degree:
3 IEC 60947-1
Network Frequency:
50/60 Hz
Circularity Profile:
ENVEOLI2206033EN
Height:
12.86 in
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Range:
PowerPact
Breaking Capacity:
AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
Terminal Identifier:
AL800M23K
Poles Description:
3P
Quantity Per Set:
1
Device Application:
distribution
Quality Labels:
CE
Product Or Component Type:
circuit breaker
Control Type:
toggle
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Electrical Connection:
lugs, load || lugs, line
Trip Unit Name:
MicroLogic 5.0
Wire Stripping Length:
25 mm
Environmental Disclosure:
ENVPEP2206033EN
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Mercury Free:
Yes
Rohs Exemption Information:
Yes
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Warranty:
18 months
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Sustainable Offer Status:
Green Premium product
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Line Rated Current:
600-600 A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Pvc Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Breaking Capacity Code:
G
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
[Ics] Rated Service Breaking Capacity:
25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
Net Weight:
32 lb(US)
Depth:
8.05 in
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Continuous Current Rating:
1
Width:
8.27 in
Ambient Air Temperature For Storage:
-50-85 °C
Local Signalling:
overload 1 1 LED amber) || 1 trip indicator green)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Product Certifications:
UL || CSA || NOM
Circuit Breaker Application:
HACR rated
Ip Degree Of Protection:
front cover IP40
Product Name:
PowerPact P
Brochure:
View
Catalog:
View
Datasheet:
View
$21,812.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 18kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose