- Circuit Breaker Application:
- HACR rated
- Warranty:
- 18 months
- Product Certifications:
- UL || CSA || NOM
- Ambient Air Temperature For Operation:
- -2-70 °C
- Pollution Degree:
- 3 IEC 60947-1
- Pvc Free:
- Yes
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Line Rated Current:
- 800-800 A
- Product Name:
- PowerPact P
- Device Application:
- distribution
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Quality Labels:
- CE
- Continuous Current Rating:
- 1
- Trip Unit Technology:
- electronic, standard, MicroLogic 5.0, LSI
- Height:
- 12.86 in
- Poles Description:
- 3P
- Breaking Capacity Code:
- G
- Circularity Profile:
- ENVEOLI2206033EN
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Network Frequency:
- 50/60 Hz
- Electrical Connection:
- lugs, load || lugs, line
- Environmental Disclosure:
- ENVPEP2206033EN
- Wire Stripping Length:
- 25 mm
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Ip Degree Of Protection:
- front cover IP40
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Depth:
- 8.05 in
- Net Weight:
- 32 lb(US)
- Rohs Exemption Information:
- Yes
- Terminal Identifier:
- AL800M23K
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Mercury Free:
- Yes
- Range:
- PowerPact
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Product Or Component Type:
- circuit breaker
- Sustainable Offer Status:
- Green Premium product
- Control Type:
- toggle
- Ambient Air Temperature For Storage:
- -50-85 °C
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Trip Unit Name:
- MicroLogic 5.0
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Eu Rohs Directive:
- Compliant with Exemptions
- Quantity Per Set:
- 1
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Local Signalling:
- overload 1 1 LED amber) || 1 trip indicator green)
- Width:
- 8.27 in