- Device Application:
- distribution
- Breaking Capacity Code:
- G
- Network Frequency:
- 50/60 Hz
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Range:
- PowerPact
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Local Signalling:
- 1 trip indicator green)
- Sustainable Offer Status:
- Green Premium product
- Warranty:
- 18 months
- Product Name:
- PowerPact P
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Poles Description:
- 3P
- Trip Unit Technology:
- electronic, ammeter, MicroLogic 6.0 A, LSIG
- Trip Unit Name:
- MicroLogic 6.0 A
- Breaking Capacity:
- AIR 65 kA 240 V AC 50/60 Hz UL 489 || AIR 35 kA 480 V AC 50/60 Hz UL 489 || AIR 18 kA 600 V AC 50/60 Hz UL 489 || Icu 50 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 35 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Circularity Profile:
- ENVEOLI2206033EN
- Environmental Disclosure:
- ENVPEP2206033EN
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Height:
- 16.16 in
- Electrical Connection:
- lugs, load || lugs, line
- Pollution Degree:
- 3 IEC 60947-1
- Awg Gauge:
- 4 x AWG 3/0...500 kcmil aluminium/copper
- Ip Degree Of Protection:
- front cover IP40
- Depth:
- 8.05 in
- [Ics] Rated Service Breaking Capacity:
- 25 kA 240 V AC 50/60 Hz IEC 60947-2 || 20 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Width:
- 8.27 in
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Terminal Identifier:
- AL1200P25K
- Tightening Torque:
- 50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Eu Rohs Directive:
- Compliant with Exemptions
- Mercury Free:
- Yes
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Line Rated Current:
- 1000-1000 A
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Product Or Component Type:
- circuit breaker
- Circuit Breaker Application:
- HACR rated
- Ambient Air Temperature For Operation:
- -2-70 °C
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Rohs Exemption Information:
- Yes
- Net Weight:
- 32 lb(US)
- Wire Stripping Length:
- 30 mm
- Control Type:
- toggle
- Continuous Current Rating:
- 0.8
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Quantity Per Set:
- 1
- Pvc Free:
- Yes
- Product Certifications:
- UL || CSA || NOM
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Ambient Air Temperature For Storage:
- -50-85 °C
- Quality Labels:
- CE