- Depth:
- 8.05 in
- Ambient Air Temperature For Operation:
- -2-70 °C
- Breaking Capacity Code:
- J
- Width:
- 8.27 in
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Quantity Per Set:
- 1
- Device Application:
- distribution
- Rohs Exemption Information:
- Yes
- Pollution Degree:
- 3 IEC 60947-1
- Mercury Free:
- Yes
- Line Rated Current:
- 800-800 A
- Local Signalling:
- overload 1 1 LED amber) || 1 trip indicator green)
- Product Name:
- PowerPact P
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Net Weight:
- 32 lb(US)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Range:
- PowerPact
- Product Certifications:
- UL || CSA || NOM
- Sustainable Offer Status:
- Green Premium product
- Phase Connection:
- ABC
- Poles Description:
- 3P
- Circuit Breaker Application:
- HACR rated
- Trip Unit Technology:
- electronic, standard, MicroLogic 5.0, LSI
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Eu Rohs Directive:
- Compliant with Exemptions
- Warranty:
- 18 months
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Control Type:
- toggle
- Terminal Identifier:
- AL800M23K
- Mounting Support:
- bracket
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Electrical Connection:
- I-Line connection, line || lugs, load
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Ip Degree Of Protection:
- front cover IP40
- Product Or Component Type:
- circuit breaker
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Wire Stripping Length:
- 25 mm
- Environmental Disclosure:
- ENVPEP2206033EN
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Mounting Mode:
- I-Line bracket)
- Mounting Height:
- 9 in
- Pvc Free:
- Yes
- Trip Unit Name:
- MicroLogic 5.0
- Quality Labels:
- CE
- Circularity Profile:
- ENVEOLI2206033EN
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Continuous Current Rating:
- 0.8
- Height:
- 12.86 in
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Network Frequency:
- 50/60 Hz
- Ambient Air Temperature For Storage:
- -50-85 °C