- Pollution Degree:
- 3 IEC 60947-1
- Product Certifications:
- UL || CSA || NOM
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Warranty:
- 18 months
- Product Name:
- PowerPact P
- Eu Rohs Directive:
- Compliant with Exemptions
- Rohs Exemption Information:
- Yes
- Trip Unit Name:
- MicroLogic 5.0
- Product Or Component Type:
- circuit breaker
- Mounting Mode:
- I-Line bracket)
- Device Application:
- distribution
- Phase Connection:
- ABC
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Circuit Breaker Application:
- HACR rated
- Terminal Identifier:
- AL1200P25K
- Wire Stripping Length:
- 30 mm
- Circularity Profile:
- ENVEOLI2206033EN
- Quantity Per Set:
- 1
- Poles Description:
- 3P
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Quality Labels:
- CE
- Range:
- PowerPact
- Ip Degree Of Protection:
- front cover IP40
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Mounting Height:
- 9 in
- Height:
- 16.16 in
- Depth:
- 8.05 in
- Net Weight:
- 32 lb(US)
- Local Signalling:
- 1 trip indicator green)
- Mounting Support:
- bracket
- Pvc Free:
- Yes
- Environmental Disclosure:
- ENVPEP2206033EN
- Mercury Free:
- Yes
- Sustainable Offer Status:
- Green Premium product
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Ambient Air Temperature For Operation:
- -2-70 °C
- Breaking Capacity Code:
- J
- Tightening Torque:
- 50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Control Type:
- toggle
- Line Rated Current:
- 1000-1000 A
- Ambient Air Temperature For Storage:
- -50-85 °C
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Continuous Current Rating:
- 0.8
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- Width:
- 8.27 in
- Awg Gauge:
- 4 x AWG 3/0...500 kcmil aluminium/copper
- Electrical Connection:
- I-Line connection, line || lugs, load
- Network Frequency:
- 50/60 Hz
- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Trip Unit Technology:
- electronic, standard, MicroLogic 5.0, LSI