Schneider Electric PJA36100U33A Molded Case Circuit Breaker 600V 1000A

(No reviews yet) Write a Review
SKU:
PJA36100U33A
UPC:
785901281924
Condition:
New
Pollution Degree:
3 IEC 60947-1
Product Certifications:
UL || CSA || NOM
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Warranty:
18 months
Product Name:
PowerPact P
Eu Rohs Directive:
Compliant with Exemptions
Rohs Exemption Information:
Yes
Trip Unit Name:
MicroLogic 5.0
Product Or Component Type:
circuit breaker
Mounting Mode:
I-Line bracket)
Device Application:
distribution
Phase Connection:
ABC
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Circuit Breaker Application:
HACR rated
Terminal Identifier:
AL1200P25K
Wire Stripping Length:
30 mm
Circularity Profile:
ENVEOLI2206033EN
Quantity Per Set:
1
Poles Description:
3P
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Quality Labels:
CE
Range:
PowerPact
Ip Degree Of Protection:
front cover IP40
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Mounting Height:
9 in
Height:
16.16 in
Depth:
8.05 in
Net Weight:
32 lb(US)
Local Signalling:
1 trip indicator green)
Mounting Support:
bracket
Pvc Free:
Yes
Environmental Disclosure:
ENVPEP2206033EN
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Ambient Air Temperature For Operation:
-2-70 °C
Breaking Capacity Code:
J
Tightening Torque:
50-50 N.m 95-240 mm² (4 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Control Type:
toggle
Line Rated Current:
1000-1000 A
Ambient Air Temperature For Storage:
-50-85 °C
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Continuous Current Rating:
0.8
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Width:
8.27 in
Awg Gauge:
4 x AWG 3/0...500 kcmil aluminium/copper
Electrical Connection:
I-Line connection, line || lugs, load
Network Frequency:
50/60 Hz
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
  • Schneider Electric PJA36100U33A Molded Case Circuit Breaker 600V 1000A
  • Schneider Electric PJA36100U33A Molded Case Circuit Breaker 600V 1000A
  • Schneider Electric PJA36100U33A Molded Case Circuit Breaker 600V 1000A
$22,334.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT P, 1000A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80% with an ABC phase connection. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose