Schneider Electric

Schneider Electric PJL36060U44A Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 25kA, lugs, Micrologic 6.0A, 80%

(No reviews yet) Write a Review
SKU:
PJL36060U44A
MPN:
PJL36060U44A
Condition:
New
Ambient Air Temperature For Storage:
-50-85°C
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Depth:
8.05 in
Product Or Component Type:
circuit breaker
Wire Stripping Length:
25 mm
Electrical Connection:
lugs, line || lugs, load
Terminal Identifier:
AL800M23K
Length:
25 mm
Ambient Air Temperature For Operation:
-25-70°C
Network Frequency:
50/60 Hz
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Continuous Current Rating:
0.8
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Warranty:
18 months
Pollution Degree:
3 IEC 60947-1
Sustainable Offer Status:
Green Premium product
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Ip Degree Of Protection:
front cover IP40
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Net Weight:
32 lb(US)
Breaking Capacity Code:
J
Environmental Disclosure:
ENVPEP2206033EN
Control Type:
toggle
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Rohs Exemption Information:
Yes
Quantity Per Set:
1
Eu Rohs Directive:
Compliant with Exemptions
Quality Labels:
CE
Product Certifications:
UL || CSA || NOM
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mercury Free:
Yes
Device Application:
distribution
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Weight:
32 lb(US)
Trip Unit Name:
MicroLogic 6.0 A
Circularity Profile:
ENVEOLI2206033EN
Pvc Free:
Yes
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Product Name:
PowerPact P
Circuit Breaker Application:
HACR rated
Trip Unit Technology:
electronic, ammeter, MicroLogic 6.0 A, LSIG
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Country of Origin:
United States
$19,787.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Ammeter with a 6.0A trip unit and an LSIG function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose