Schneider Electric

Schneider Electric PJL36060U63AE1 Circuit breaker, PowerPacT P, 600A, 3 pole, 600VAC, 25kA, lugs, Micrologic 5.0P, 80%, modbus

(No reviews yet) Write a Review
SKU:
PJL36060U63AE1
MPN:
PJL36060U63AE1
Condition:
New
Length:
25 mm
Warranty:
18 months
Device Application:
distribution
Continuous Current Rating:
0.8
Local Signaling:
overload 1 trip indicator green) || 1 trip indicator green) || trip causes 1 trip indicator green)
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Line Rated Current:
600-600 A
Weight:
32 lb(US)
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Ip Degree Of Protection:
front cover IP40
Product Or Component Type:
circuit breaker
Rohs Exemption Information:
Yes
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circularity Profile:
ENVEOLI2206033EN
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Range:
PowerPact
Product Certifications:
UL || CSA || NOM
Sustainable Offer Status:
Green Premium product
Mounting Mode:
unit mount lug)
Ambient Air Temperature For Storage:
-50-85°C
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Trip Unit Name:
MicroLogic 5.0 P
Quality Labels:
CE
Product Name:
PowerPact P
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Electrical Connection:
lugs, line || lugs, load
Mercury Free:
Yes
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Network Frequency:
50/60 Hz
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Trip Unit Technology:
electronic, power, MicroLogic 5.0 P, LSI
Poles Description:
3P
Communication Interface:
Modbus
Control Type:
toggle
Pvc Free:
Yes
Ambient Air Temperature For Operation:
-25-70°C
Breaking Capacity Code:
J
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Pollution Degree:
3 IEC 60947-1
Terminal Identifier:
AL800M23K
Mounting Support:
lug
Country of Origin:
United States
Circuit Breaker Application:
HACR rated
Depth:
8.05 in
$22,332.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Power with a 5.0P trip unit and an LSI function with Modbus communications. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 600A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.