Schneider Electric

Schneider Electric PJL36080CU33A Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
PJL36080CU33A
UPC:
785901917977
Condition:
New
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Mounting Support:
lug
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Rohs Exemption Information:
Yes
Poles Description:
3P
Device Application:
distribution
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Continuous Current Rating:
1
Eu Rohs Directive:
Compliant with Exemptions
Electrical Connection:
lugs, line || lugs, load
Depth:
8.05 in
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Network Frequency:
50/60 Hz
Sustainable Offer Status:
Green Premium product
Breaking Capacity Code:
J
Pollution Degree:
3 IEC 60947-1
Circularity Profile:
ENVEOLI2206033EN
Pvc Free:
Yes
Width:
8.27 in
Trip Unit Name:
MicroLogic 5.0
Product Or Component Type:
circuit breaker
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Height:
12.86 in
Product Name:
PowerPact P
Ip Degree Of Protection:
front cover IP40
Net Weight:
32 lb(US)
Ambient Air Temperature For Operation:
-2-70 °C
Mounting Mode:
unit mount lug)
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Line Rated Current:
800-800 A
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Control Type:
toggle
Local Signalling:
overload 1 trip indicator green) || 1 trip indicator green)
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Range:
PowerPact
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Quantity Per Set:
1
Mercury Free:
Yes
Wire Stripping Length:
25 mm
Quality Labels:
CE
Product Certifications:
UL || CSA || NOM
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Environmental Disclosure:
ENVPEP2206033EN
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Terminal Identifier:
AL800M23K
Warranty:
18 months
Circuit Breaker Application:
HACR rated
Ambient Air Temperature For Storage:
-50-85 °C
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
Brochure:
View
Catalog:
View
Datasheet:
View
$23,187.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has lugs on both the line and load sides. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 100%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose