- Operating Altitude:
- < 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
- Width:
- 8.27 in
- Poles Description:
- 3P
- Pvc Free:
- Yes
- Depth:
- 8.05 in
- [Ics] Rated Service Breaking Capacity:
- 35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Product Certifications:
- UL || CSA || NOM
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Ambient Air Temperature For Storage:
- -50-85 °C
- Number Of Slots:
- 2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
- Ambient Air Temperature For Operation:
- -2-70 °C
- Terminal Identifier:
- AL800M23K
- Long Time Pick-Up Adjustment Range:
- 0.4...1 x Ir
- Product Name:
- PowerPact P
- Sustainable Offer Status:
- Green Premium product
- Rohs Exemption Information:
- Yes
- Line Rated Current:
- 800-800 A
- Pollution Degree:
- 3 IEC 60947-1
- Warranty:
- 18 months
- Mercury Free:
- Yes
- Local Signalling:
- overload 1 1 LED amber) || 1 trip indicator green)
- Trip Unit Technology:
- electronic, standard, MicroLogic 5.0, LSI
- Height:
- 12.86 in
- [Ui] Rated Insulation Voltage:
- 750 V IEC 60947-2
- Eu Rohs Directive:
- Compliant with Exemptions
- Breaking Capacity Code:
- J
- Control Type:
- toggle
- [Uimp] Rated Impulse Withstand Voltage:
- 8 kV IEC 60947-2
- [Ue] Rated Operational Voltage:
- 600 V AC 50/60 Hz UL 489
- Trip Unit Name:
- MicroLogic 5.0
- Range:
- PowerPact
- Circuit Breaker Application:
- HACR rated
- Ip Degree Of Protection:
- front cover IP40
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Quality Labels:
- CE
- Quantity Per Set:
- 1
- Tightening Torque:
- 50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
- Breaking Capacity:
- AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
- Network Frequency:
- 50/60 Hz
- Wire Stripping Length:
- 25 mm
- Awg Gauge:
- 3 x AWG 3/0...500 kcmil aluminium/copper
- Electrical Connection:
- lugs, line || lugs, load
- Product Or Component Type:
- circuit breaker
- Standards:
- UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
- Mounting Support:
- lug
- Net Weight:
- 32 lb(US)
- Mounting Mode:
- unit mount lug)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
- Environmental Disclosure:
- ENVPEP2206033EN
- Circularity Profile:
- ENVEOLI2206033EN
- Continuous Current Rating:
- 0.8
- Device Application:
- distribution