Schneider Electric

Schneider Electric PJP36080U33A Molded Case Circuit Breaker 600V 800A

(No reviews yet) Write a Review
SKU:
PJP36080U33A
UPC:
3.60649E+12
Condition:
New
Breaking Capacity Code:
J
Trip Unit Name:
MicroLogic 5.0
Quantity Per Set:
1
Width:
8.27 in
Circuit Breaker Application:
HACR rated
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Net Weight:
32 lb(US)
Pvc Free:
Yes
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000 || IEC 60947-2
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 overcurrent trip switch SDE plug-in) || 1 voltage release MN or MX plug-in)
Control Type:
toggle
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Tightening Torque:
50-50 N.m 95-240 mm² (3 x AWG 3/0...500 kcmil) || 1.0-1.3 N.m
Network Frequency:
50/60 Hz
Sustainable Offer Status:
Green Premium product
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Device Application:
distribution
Product Name:
PowerPact P
Awg Gauge:
3 x AWG 3/0...500 kcmil aluminium/copper
Product Certifications:
UL || CSA || NOM
Terminal Identifier:
AL800M23K
Environmental Disclosure:
ENVPEP2206033EN
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Line Rated Current:
800-800 A
Depth:
8.05 in
Warranty:
18 months
Ambient Air Temperature For Operation:
-2-70 °C
Circularity Profile:
ENVEOLI2206033EN
Quality Labels:
CE
Height:
12.86 in
Poles Description:
3P
Product Or Component Type:
circuit breaker
Mounting Support:
lug
Electrical Connection:
terminal nut, line || lugs, load
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Ip Degree Of Protection:
front cover IP40
Pollution Degree:
3 IEC 60947-1
Eu Rohs Directive:
Compliant with Exemptions
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Wire Stripping Length:
25 mm
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Mercury Free:
Yes
Continuous Current Rating:
0.8
Long Time Pick-Up Adjustment Range:
0.4...1 x Ir
Ambient Air Temperature For Storage:
-50-85 °C
Rohs Exemption Information:
Yes
Local Signalling:
overload 1 1 LED amber) || 1 trip indicator green)
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Mounting Mode:
unit mount lug)
Range:
PowerPact
Brochure:
View
Catalog:
View
Datasheet:
View
$15,909.00

Description

PowerPacT P-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT P-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT P circuit breakers are available in 2, 3, and 4-pole unit mount, I-Line, or drawout construction. This unit has terminal nuts on the line side and lugs on the load side. This PowerPacT P, 800A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. This circuit breaker has a continuous current rating of 80%. PowerPacT P circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose