Schneider Electric QDA220804 Molded Case Circuit Breaker 240V 80A

(No reviews yet) Write a Review
SKU:
QDA220804
UPC:
785901832737
Condition:
New
Mechanical Durability:
1000 cycles loaded || 5000 cycles no load
Device Application:
distribution
Range:
PowerPact
Rohs Exemption Information:
Yes
Eu Rohs Directive:
Compliant with Exemptions
Circuit Breaker Application:
HACR rated
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Tightening Torque:
28-28 N.m 25-150 mm² (AWG 4...300 kcmil)
Product Certifications:
UL || CSA || NOM
Magnetic Hold Current:
1000 A
Product Or Component Type:
circuit breaker
Phase Connection:
BC
Pvc Free:
Yes
Line Rated Current:
80 A
Warranty:
18 months
Network Frequency:
50/60 Hz
Height:
6.47 in
Utilisation Category:
category A
Width:
3.00 in
Standards:
UL || CSA || NEMA || NOM-003-SCFI-2000
Wire Stripping Length:
22 mm
Breaking Capacity Code:
D
Environmental Disclosure:
ENVPEP1406032EN
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Trip Unit Technology:
thermal-magnetic
Control Type:
operating handle
Local Signalling:
1 trip indicator green)
[Uimp] Rated Impulse Withstand Voltage:
8 kV UL
Continuous Current Rating:
0.8
Electrical Connection:
I-Line connection, line || lugs, load
[Ue] Rated Operational Voltage:
240 V AC 50/60 Hz UL
Mounting Support:
bracket
Depth:
3.93 in
Product Name:
PowerPact Q
Mercury Free:
Yes
Sustainable Offer Status:
Green Premium product
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Halogen Content Performance:
Halogen free product
Line Rated Current:
80-80 A
Mounting Height:
3 in
Mounting Mode:
I-Line bracket)
Circularity Profile:
N/A
Breaking Capacity:
25 kA 120/208 V AC 50/60 Hz UL || 25 kA 240 V AC 50/60 Hz UL
Poles Description:
2P
Magnetic Tripping Current:
1800-1800 A
Ambient Air Temperature For Operation:
40-70 °C
Catalog:
View
Datasheet:
View
  • Schneider Electric QDA220804 Molded Case Circuit Breaker 240V 80A
  • Schneider Electric QDA220804 Molded Case Circuit Breaker 240V 80A
  • Schneider Electric QDA220804 Molded Case Circuit Breaker 240V 80A
$1,202.00

Description

PowerPacT Q-Frame circuit breakers are used for overcurrent protection and switching on 240VAC systems. They are rated for 240VAC operational voltage and provide thermal magnetic trip protection. PowerPacT Q circuit breakers are available in 2 and 3-pole unit mount and I-Line constructions. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. This unit has I-Line terminations on the line side and mechanical lugs on the load side. This PowerPacT Q, 80A, 2 pole, circuit breaker has an interrupting rating of 25kA at 208Y/120VAC and 240VAC. This circuit breaker has a continuous current rating of 80% with a BC phase connection. PowerPacT Q circuit breakers comply to UL, CSA, and NOM standards and are IEC certified.
View AllClose