Schneider Electric RE48AML12MW 4 Function Plug Timer 2 C/O

(No reviews yet) Write a Review
SKU:
RE48AML12MW
UPC:
3389110649598
Condition:
New
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Breaking Capacity:
1250 VA
Relative Humidity:
93-93 % without condensation IEC 60068-2-3
Contacts Type And Composition:
2 C/O timed contacts, AgNi (cadmium free)
Local Signalling:
for output relay state 1 LED (yellow) || for flashing: relay energised timing in progress LED indicator (green) || for on steady: relay energised, no timing in progress LED indicator (green)
China Rohs Regulation:
X
Ip Degree Of Protection:
IP40 IEC 60529 housing) || IP50 IEC 60529 front face)
Vibration Resistance:
0.35 mm 10-55 Hz)IEC 60068-2-6
Temperature Drift:
+/- 0.02 %/°C of the maximum setting value IEC 61812-1
Minimum Pulse Duration:
20 ms
Immunity To Voltage Dips:
30 % / 10 ms IEC 61000-4-11 || 60 % / 100 ms IEC 61000-4-11 || 95 % / 5 s IEC 61000-4-11
Resistance To Fast Transients:
2 kV IEC 61000-4-4 level 4 capacitive connecting clip) || 4 kV IEC 61000-4-4 level 4 direct)
Range Of Product:
Harmony Timer Relays
Ambient Air Temperature For Operation:
-20-50 °C
Maximum Switching Voltage:
250 V AC/DC
Warranty:
18 months
Sustainable Offer Status:
Green Premium product
Reset Time:
25 ms on de-energisation
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Environmental Disclosure:
ENVPEP1512002EN
Mounting Support:
base mounted: socket || panel mounted: system supplied with the product
Product Certifications:
UL || cULus || CSA || C-tick
Repeat Accuracy:
+/- 0.2 % of the maximum setting value IEC 61812-1
California Proposition 65:
WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other repr
Minimum Switching Current:
100 mA
Marking:
CE
Power Consumption In W:
0.5 W 24 V || 1.7 W 240 V
Standards:
IEC 61812-1 || EN 50081-1/2 || 93/68/EEC || 89/336/EEC || EN 50082-1/2 || IEC 60669-2-3 || 73/23/EEC
Output Voltage:
240 V 5 A AC-12 || 30 V 2 A DC-13 || 240 V 1.5 A AC-15
Housing Material:
self-extinguishing
Electrical Connection:
plug-in sub-base 11
Component Name:
RE48A
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Immunity To Radioelectric Fields:
10 V 0.15...80 MHz)IEC 61000-4-6 level 3
Resistance To Electromagnetic Fields:
10 V/m 26 MHz to 1 GHz IEC 61000-4-3 level 3
Immunity To Microbreaks:
10 ms
Ambient Air Temperature For Storage:
-40-70 °C
Setting Accuracy Of Time Delay:
+/- 5 % of full scale 25 °C IEC 61812-1
On-Load Factor:
1
Surge Withstand:
1 kV differential mode IEC 61000-4-5 level 3 || 2 kV common mode IEC 61000-4-5 level 3
Power Consumption In Va:
1.1 VA 24 V || 4.8 VA 240 V
Line Rated Current:
0.208333333333333
Protection Against Electric Shocks:
4 kV class III IEC 60664-1 || 4 kV class III IEC 61812-1
Electrical Durability:
100000 cycles
Discrete Output Type:
relay
Voltage Drift:
+/- 0.2 %/V of the maximum setting value 48...240 V || +/- 1 %/V of the maximum setting value 24...48 V
Humidity Drift:
+/- 0.05 %/%RH of the maximum setting value IEC 61812-1
Net Weight:
0.14 kg
Product Or Component Type:
multifunction relay
Pick Up Duration:
55 ms
Mercury Free:
Yes
Product Front Plate Size:
48 x 48 mm
Circularity Profile:
ENVEOLI1512002EN
Control Type:
selector switch front panel
Voltage Range:
0.85...1.1 Us AC || 0.9...1.1 Us DC
Maximum Switching Current:
0.208333333333333
Time Delay Type:
power on-delay || interval || off-delay || symmetrical flashing
[Us] Rated Supply Voltage:
24...240 V AC/DC 50/60 Hz
Resistance To Electrostatic Discharge:
6 kV in contact IEC 61000-4-2 level 3 || 8 kV in air IEC 61000-4-2 level 3
Disturbance Radiated/Conducted:
class B 0.15...30 MHz EN 55022 (EN 55011 group 1)
Time Delay Range:
0.5...30 s || 5...300 s || 0.2...12 min || 0.5...30 h || 2...120 s || 0.05...3 s || 0.2...12 s || 0.02...1.2 s || 2...120 min || 5...300 min || 0.5...30 min || 5...300 h || 2...120 h || 0.2...12 h
Rohs Exemption Information:
Yes
Dielectric Strength:
1 kV 1 mA/1 minute IEC 61812-1
Mechanical Durability:
30000000 cycles
$86.00

Description

This Harmony RE48 timing relay can be set between 0.2 seconds and 300 hours, has an output rating of 5A, is 48mm wide and can be supplied with 24V to 240V AC. It is a plug-in device, meaning it is quick and easy to install with the need for tools. It also offers a sealable cover, simple and precise settings with rotary trimmers. It is designed for both panel mooting or socket plug in, this gives more flexibility in designing installations and stocking spares. Multi function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. Status display with 2 LEDs, visually inspect the status of you system without specialized tools. 0 0 0 0 0 0 0 0 0 0 0 0 0
View AllClose