Schneider Electric RJF36200U33A Molded Case Circuit Breaker 600V 2000A

(No reviews yet) Write a Review
SKU:
RJF36200U33A
UPC:
785901495604
Condition:
New
Mounting Mode:
unit mount busbar)
Continuous Current Rating:
0.8
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Number Of Slots:
2 auxiliary switch OF plug-in) || 1 alarm switch SD plug-in) || 1 voltage release MN or MX plug-in)
Quality Labels:
CE
Height:
16.24 in
Circularity Profile:
ENVEOLI2206034EN
Mercury Free:
Yes
California Proposition 65:
WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information
Operating Altitude:
< 6561.68 ft (2000 m) without derating || 13123.36 ft (4000 m) with derating
Line Rated Current:
2000-2000 A
Environmental Disclosure:
ENVPEP2206034EN
Eu Rohs Directive:
Compliant with Exemptions
Device Application:
distribution
Product Name:
PowerPact R
Product Certifications:
UL || CSA || NOM
[Uimp] Rated Impulse Withstand Voltage:
8 kV IEC 60947-2
Poles Description:
3P
Suitability For Isolation:
yes IEC 60947-2
Breaking Capacity:
AIR 100 kA 240 V AC 50/60 Hz UL 489 || AIR 65 kA 480 V AC 50/60 Hz UL 489 || AIR 25 kA 600 V AC 50/60 Hz UL 489 || Icu 65 kA 240 V AC 50/60 Hz IEC 60947-2 || Icu 50 kA 380/415 V AC 50/60 Hz IEC 60947-2
Network Frequency:
50/60 Hz
Range:
PowerPact
Rohs Exemption Information:
Yes
Ip Degree Of Protection:
IP40
Ambient Air Temperature For Storage:
-50-85 °C
Awg Gauge:
AWG 3/0...750 kcmil aluminium/copper
Trip Unit Technology:
electronic, standard, MicroLogic 5.0, LSI
Control Type:
operating handle
Utilisation Category:
category A
Mounting Support:
busbar
[Ics] Rated Service Breaking Capacity:
35 kA 240 V AC 50/60 Hz IEC 60947-2 || 25 kA 380/415 V AC 50/60 Hz IEC 60947-2
Circuit Breaker Application:
HACR rated
[Ui] Rated Insulation Voltage:
750 V IEC 60947-2
Product Or Component Type:
circuit breaker
Tightening Torque:
68-68 N.m 50-400 mm² (AWG 1/0...750 kcmil) || 68-68 N.m 50-150 mm² (2 x AWG 1/0...2 x 300 kcmil)
Sustainable Offer Status:
Green Premium product
Warranty:
18 months
Quantity Per Set:
1
Trip Unit Name:
MicroLogic 5.0
Breaking Capacity Code:
J
Net Weight:
52 lb(US)
Wire Stripping Length:
35 mm
[Ue] Rated Operational Voltage:
600 V AC 50/60 Hz UL 489
Standards:
UL || CSA || NEMA || NMX J-266 || IEC 60947-2
Depth:
14.49 in
Ambient Air Temperature For Operation:
-25-70 °C
Electrical Connection:
busbar connection, line || busbar connection, load
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Halogen Content Performance:
Halogen free plastic parts product
Width:
16.53 in
Pollution Degree:
3 IEC 60947-1
Local Signalling:
alarm 1 LED yellow)long-time pick up)
Pvc Free:
Yes
Terminal Identifier:
AL2500RK
$24,675.00

Description

PowerPacT R-Frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. PowerPacT R-Frame circuit breakers have either a fixed long time electronic trip unit, ET 1.0I, or Micrologic trip units. Micrologic trip units can be interchanged in the field to allow for maximum flexibility; the basic electronic trip unit doesn't have that interchangeability. This circuit breaker has a Micrologic Interchangeable Standard Trip with a 5.0 trip unit and an LSI function. All PowerPacT circuit breakers have an integral push-to-trip button in the cover to manually trip the circuit breaker. PowerPacT R circuit breakers are available in 2, 3, and 4-pole unit mount and I-Line construction (I-Line construction is available for 1000A and 1200A rated circuit breakers only). This unit has a busbar connection. This PowerPacT P, 2000A, 3 pole, circuit breaker has an interrupting rating of 25kA at 600VAC. The circuit breaker has a continuous current rating of 80%. PowerPacT R circuit breakers comply to UL, CSA, NOM, and IEC standards and are CE marked.
View AllClose