This Harmony RM22JA control relay allows monitoring of overcurrent control. This modular control relay is ideal for monitoring of electrical values and current variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
- Setting Accuracy Of The Switching Threshold:
- +/- 10 % of the full scale
- Ambient Air Temperature For Storage:
- -40-70 °C
- Product Certifications:
- EAC || CSA || CE || RCM || CCC || UL || GL
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Relay Type:
- current control relay
- Maximum Power Consumption In Va:
- 3.5 VA
- Immunity To Microbreaks:
- 50 ms
- Mounting Support:
- 35 mm DIN rail conforming to IEC 60715
- Time Delay Type:
- without 0.1...30 s
- Relative Humidity:
- 93-97 % 25-55 °C IEC 60068-2-30
- Hysteresis:
- 5-50 % adjustable threshold setting
- Standards:
- IEC 60255-1
- Shock Resistance:
- 15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27
- Net Weight:
- 0.11 kg
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Environmental Disclosure:
- ENVPEP1504008EN
- Control Type:
- with test button
- [Us] Rated Supply Voltage:
- AC/DC non self-powered
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)
- Electromagnetic Compatibility:
- immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 || immunity for industrial environments conforming to IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments
- Overvoltage Category:
- III IEC 60664-1 || III UL 508
- Relay Monitored Parameters:
- overcurrent detection
- Product Or Component Type:
- current control relay
- Output Contacts:
- 2 C/O
- Resistance Across Terminals:
- 2.5 Ohm E1-M terminals || 0.5 Ohm E2-M terminals || 0.1 Ohm E3-M terminals
- Insulation Resistance:
- > 100 MOhm 500 V DC IEC 60255-27
- Maximum Measuring Cycle:
- 100 ms measurement cycle as true rms value
- Safety Reliability Data:
- MTTFd = 296.8 years || B10d = 270000
- Range Of Product:
- Harmony Control Relays
- Utilisation Category:
- AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1
- Dielectric Test Voltage:
- 2.5 kV AC 50 Hz, 1 min IEC 60255-27
- Local Signalling:
- for relay ON LED (yellow) || for power ON LED (green)
- Measurement Error:
- < 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation
- Maximum Switching Current:
- 8 A AC
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Time Delay Drift:
- <= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
- Insulation:
- between supply and measurement
- Measurement Range:
- 4...40 mA AC/DC E1-M terminals || 20...200 mA E2-M terminals || 100...1000 mA E3-M terminals || 4 mA...1 A current AC/DC 50/60 Hz
- Control Circuit Voltage Limits:
- 15 % + 10 % Un
- Pollution Degree:
- 3 IEC 60664-1 || 3 UL 508
- Repeat Accuracy:
- +/- 0.5 % input and measurement circuit || +/- 0.2 % time delay
- Ambient Air Temperature For Operation:
- -20-50 °C 60 Hz || -20-60 °C 50 Hz
- Contacts Type And Composition:
- 2 C/O
- Switching Capacity In Va:
- 2000 VA
- Contacts Material:
- cadmium free
- China Rohs Regulation:
- X
- Relay Name:
- RM22JA
- Electrical Durability:
- 100000 cycles
- Nominal Output Current:
- 0.333333333333333
- Vibration Resistance:
- 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
- Housing Material:
- self-extinguishing plastic
- Internal Input Resistance:
- 0.1 Ohm || 2.5 Ohm || 0.5 Ohm
- Rohs Exemption Information:
- Yes
- Maximum Switching Voltage:
- 250 V AC
- Mercury Free:
- Yes
- Mechanical Durability:
- 10000000 cycles
- Run-Up Delay At Power-Up:
- 0.3 s
- Sustainable Offer Status:
- Green Premium product
- Connections - Terminals:
- screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end |
- Circularity Profile:
- ENVEOLI1504008EN
- Reset Time:
- 1500 ms at maximum voltage
- Response Time:
- <= 500 ms
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Supply Voltage Limits:
- 20.4-264 V AC/DC
- Width:
- 22.5 mm
- Minimum Switching Current:
- 10 mA 5 V DC
- Setting Accuracy Of Time Delay:
- 0.916666666666667
- Threshold Setting:
- 10...100 %
- Switching Threshold Drift:
- <= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
- Maximum Power Consumption In W:
- 1.5 W DC