Schneider Electric

Schneider Electric RM22TU21 3 Phase Undervoltage Control Relay Rm22-

(No reviews yet) Write a Review
SKU:
RM22TU21
UPC:
3606480792168
Condition:
New
Relay Name:
RM22TR
Relative Humidity:
93-97 % 25-55 °C IEC 60068-2-30
Product Or Component Type:
3-phase control relay
Rohs Exemption Information:
Yes
Switching Capacity In Va:
2000 VA
Width:
22.5 mm
Repeat Accuracy:
+/- 0.5 % input and measurement circuit
Power Consumption In Va:
10-10 VA 240 V AC 60 Hz
Phase:
3 phase
Switching Threshold Drift:
<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
Ambient Air Temperature For Storage:
-40-70 °C
Environmental Disclosure:
ENVPEP1504008EN
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Vibration Resistance:
0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
Electromagnetic Compatibility:
immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 || immunity for industrial environments conforming to IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments
Output Contacts:
2 C/O
Product Certifications:
RCM || CE || CSA || GL || CCC || UL || EAC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Range Of Product:
Harmony Control Relays
Control Type:
with test button
Shock Resistance:
15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27
Supply Voltage Limits:
160-288 V AC
Maximum Measuring Cycle:
150 ms measurement cycle as true rms value
Time Delay Drift:
<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
Supply Frequency:
50...60 Hz +/- 10 %
China Rohs Regulation:
X
Run-Up Delay At Power-Up:
650 ms
Electrical Durability:
100000 cycles
Hysteresis:
2-2 % fixed selectable
Threshold Adjustment Voltage:
2...20 % of Un selected
Immunity To Microbreaks:
10 ms
Setting Accuracy Of Time Delay:
0.916666666666667
[Us] Rated Supply Voltage:
self-powered
Ip Degree Of Protection:
IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)
Housing Material:
self-extinguishing plastic
Safety Reliability Data:
B10d = 350000 || MTTFd = 388.1 years
Minimum Switching Current:
10 mA 5 V DC
Measurement Error:
< 1 % over the whole range with voltage variation || < 0.05 %/°C with temperature variation
Mechanical Durability:
10000000 cycles
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Maximum Switching Voltage:
250 V AC
Setting Accuracy Of The Switching Threshold:
+/- 10 % of the full scale
Mounting Support:
35 mm DIN rail conforming to IEC 60715
Circularity Profile:
ENVEOLI1504008EN
Pollution Degree:
3 IEC 60664-1 || 3 UL 508
Ambient Air Temperature For Operation:
-20-50 °C 60 Hz || -20-60 °C 50 Hz AC/DC
Connections - Terminals:
screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end |
Insulation Resistance:
> 100 MOhm 500 V DC IEC 60255-27
Reset Time:
1500 ms at maximum voltage
Dielectric Test Voltage:
2.5 kV AC 50 Hz, 1 min IEC 60255-27
Nominal Output Current:
0.333333333333333
Sustainable Offer Status:
Green Premium product
[Us] Rated Supply Voltage:
AC/DC
Net Weight:
0.09 kg
Control Circuit Voltage Limits:
20 % + 20 % Un
Overvoltage Category:
III IEC 60664-1 || III UL 508
Relay Type:
control relay
Standards:
IEC 60255-1
Voltage Range:
200...240 V phase to phase
Contacts Material:
cadmium free
Measurement Range:
200...240 V voltage AC
Mercury Free:
Yes
Utilisation Category:
AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1
Mounting Position:
any position
Maximum Switching Current:
8 A AC
Voltage Detection Threshold:
< 100 V AC
Status Led:
LED (Yellow) relay ON || LED (Green) power ON
Tightening Torque:
0.6-1 N.m IEC 60947-1
Time Delay Type:
without
Relay Monitored Parameters:
undervoltage detection || phase sequence || phase failure detection
Response Time:
<= 300 ms
Contacts Type And Composition:
2 C/O
Catalog:
View
Datasheet:
View
$151.30

Description

This Harmony RM22-TU relay allows monitoring of phase and undervoltage/overtage in 3-phase networks." "This modular multi function 3-phase control relay is ideal for monitoring of electrical values in industrial and building control panels." "It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water." "It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device." "It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers." "It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting." "multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC." 0 0 0 0 0 0 0 0 0
View AllClose