This Harmony RM22-UA relay allows monitoring of voltage control in single phase networks. This modular multi function single phase voltage control relay is ideal for monitoring of electrical values in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market slim form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a diagnostic button, sealable cover, simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- Switching Capacity In Va:
- 2000 VA
- Shock Resistance:
- 15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27
- [Us] Rated Supply Voltage:
- AC non self-powered
- Mechanical Durability:
- 10000000 cycles
- Reset Time:
- 1500 ms at maximum voltage
- China Rohs Regulation:
- X
- Overvoltage Category:
- III IEC 60664-1
- Product Certifications:
- RCM || GL || CCC || CSA || UL || EAC || CE
- Control Type:
- with test button
- Width:
- 22.5 mm
- Measurement Range:
- 15...500 V voltage AC/DC 50/60 Hz
- Relative Humidity:
- 93-97 % 25-55 °C IEC 60068-2-30
- Supply Voltage Limits:
- 323-456.5 V AC
- Supply Circuit Type:
- DC
- Power Consumption In Va:
- 8-8 VA AC
- Response Time:
- <= 500 ms
- Ambient Air Temperature For Operation:
- -20-50 °C 60 Hz || -20-60 °C 50 Hz
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Mercury Free:
- Yes
- Rohs Exemption Information:
- Yes
- Connections - Terminals:
- screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end |
- Compatibility Code:
- RM22
- Nominal Output Current:
- 0.333333333333333
- Circularity Profile:
- ENVEOLI1504008EN
- Ambient Air Temperature For Storage:
- -40-70 °C
- Phase:
- 1 phase
- Contacts Type And Composition:
- 2 C/O
- Time Delay Type:
- adjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault
- Range Of Product:
- Harmony Control Relays
- Safety Reliability Data:
- MTTFd = 308.2 years || B10d = 290000
- Repeat Accuracy:
- +/- 0.5 % input and measurement circuit || +/- 2 % time delay
- Electrical Durability:
- 100000 cycles
- Vibration Resistance:
- 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
- Relay Type:
- voltage control relay
- Mounting Support:
- 35 mm DIN rail conforming to IEC 60715
- Maximum Measuring Cycle:
- 100 ms measurement cycle as true rms value
- Insulation Resistance:
- > 100 MOhm 500 V DC
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Output Contacts:
- 2 C/O
- Net Weight:
- 0.11 kg
- Immunity To Microbreaks:
- 10 ms
- Minimum Switching Current:
- 10 mA 5 V DC
- Run-Up Delay At Power-Up:
- 600 ms
- Resistance Across Terminals:
- 150 kOhm E2-M terminals || 300 kOhm E1-M terminals || 500 kOhm E3-M terminals
- Dielectric Test Voltage:
- 2.5 kV AC 50 Hz, 1 min IEC 60255-27
- Relay Monitored Parameters:
- overvoltage or undervoltage detection || undervoltage and overvoltage in window mode
- Maximum Switching Voltage:
- 250 V AC
- Insulation:
- between supply and measurement
- Standards:
- IEC 60255-1
- Product Or Component Type:
- voltage control relay
- Pollution Degree:
- 3 IEC 60664-1
- Hysteresis:
- 3-3 % fixed full scale for window mode || 5-50 % adjustable threshold setting
- Measurement Error:
- < 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation
- Electromagnetic Compatibility:
- immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 || immunity for industrial environments conforming to IEC 61000-6-2 || emission standard for industrial environments conforming to IEC 61000-6-4 || ele
- Housing Material:
- self-extinguishing plastic
- Functionality:
- undervoltage and overvoltage in window mode
- Relay Name:
- RM22UA
- Contacts Material:
- cadmium free
- Sustainable Offer Status:
- Green Premium product
- Environmental Disclosure:
- ENVPEP1504008EN
- Utilisation Category:
- AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1
- Maximum Switching Current:
- 8 A AC
- Catalog:
- View
- Datasheet:
- View