Schneider Electric RM35S0MW Speed Control Relay 24-240Vac/Dc

(No reviews yet) Write a Review
SKU:
RM35S0MW
UPC:
3389119405256
Condition:
New
Time Delay Type:
adjustable 0.6...60 s Ti- inhibition time delay upon startup
Measurement Error:
+/- 0.1 %/°C with temperature variation || < +/- 1 % over the whole range with voltage variation
Input Compatibility:
3-wire sensor (E1) PNP or NPN, 12 V, 50 mA || NAMUR sensor (E2), 12 V, 1.5 kOhm || voltage input (E1), 0...30 V, 9.5 kOhm >= 4.5 V <= 1 V || volt-free contact input (E1), 12 V, 9.5 kOhm
China Rohs Regulation:
X
Product Certifications:
C-tick || GOST || UL || GL || CSA
Connections - Terminals:
screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end || scr
Polarity:
reversible polarity on DC supply
Rohs Exemption Information:
Yes
Minimum Switching Current:
10 mA 5 V DC
Sustainable Offer Status:
Green Premium product
Repeat Accuracy:
+/- 0.5 % input and measurement circuit || +/- 0.5 % time delay
Status Led:
1 LED Green power ON || 1 LED Yellow inhibit || 1 LED Yellow relay (R)
Maximum Switching Voltage:
250 V AC/DC
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Maximum Power Consumption In W:
3 W DC
Overvoltage Category:
III IEC 60664-1
Electromagnetic Compatibility:
emission standard for industrial environments IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments IEC 61000-6-3 || immunity for industrial environments NF EN/IEC 61000-6-2
Housing Material:
self-extinguishing plastic
Product Or Component Type:
speed control relay
Dielectric Test Voltage:
2 kV AC 50 Hz
Vibration Resistance:
0.35 mm 5-57.6 Hz)IEC 60068-2-6/IEC 60255-21-1 || 1 gn 57.6-150 Hz)IEC 60068-2-6/IEC 60255-21-1
Relay Name:
RM35S
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Time Delay Range:
0.6...60 s adjustable on energisation 0...10 % of the full scale value)
Shock Resistance:
15 gn 11 ms IEC 60255-21-1
Nominal Output Current:
0.208333333333333
Supply Voltage Limits:
20.4-264 V AC/DC
Circularity Profile:
ENVEOLI1504008EN
Marking:
CE : EMC 89/336/EEC || CE : 73/23/EEC
Pollution Degree:
3 IEC 60664-1
Relative Humidity:
95-95 % 55-55 °C IEC 60068-2-30
Relay Type:
speed control relays
Measurement Accuracy:
+/- 10 % of the full scale value
Mercury Free:
Yes
Mechanical Durability:
30000000 cycles
Environmental Disclosure:
ENVPEP1504008EN
Tightening Torque:
0.6-1 N.m IEC 60947-1
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Operating Rate:
<= 360 operations/hour full load
Electrical Durability:
100000 cycles
Measurement Range:
0.05...0.5 s || 0.5...5 min || 1...10 min || 1...10 s || 0.5...5 s || 0.1...1 s || 0.1...1 min
Switching Capacity In Va:
1250 VA
Control Type:
without test button
Control Circuit Voltage Limits:
15 % + 10 % Un
Supply Frequency:
50/60 Hz +/- 10 %
Width:
35 mm
[Ui] Rated Insulation Voltage:
250 V IEC 60664-1
Utilisation Category:
AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
Hysteresis:
5-5 % threshold
Mounting Support:
35 mm symmetrical DIN rail conforming to IEC 60715
Ip Degree Of Protection:
IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
Run-Up Delay At Power-Up:
0.05 s
Maximum Supply Current For Sensors:
40 mA < 24 V AC 25 °C || 40 mA < 24 V DC 25 °C || 50 mA 24...240 V AC || 50 mA 24...240 V DC
Output Contacts:
1 C/O
Ambient Air Temperature For Operation:
-20-50 °C
Maximum Power Consumption In Va:
5 VA AC
Impulse Duration:
>= 5 ms high state || >= 5 ms low state
Warranty:
18 months
Threshold Setting:
10...100 %
Measurement Range:
0.05...600 s AC/DC
Non-Dissipating Shock Wave:
4 kV
Immunity To Microbreaks:
50 ms
Range Of Product:
Harmony Control Relays
Standards:
NF EN 60255-6 || IEC 60255-6
Relay Monitored Parameters:
overspeed || underspeed
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Response Time:
15 ms max (on crossing the threshold)
[Us] Rated Supply Voltage:
11.5...12.5 V
Ambient Air Temperature For Storage:
-40-70 °C
Input Frequency:
0.0017-20 Hz
Contacts Material:
cadmium free
Reset Time:
50 ms contact S2 in memory mode on time delay || 1 s supply Un in memory mode on time delay
Operating Position:
any position without derating
Insulation Resistance:
> 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || > 500 MOhm 500 V DC between supply and relay ou
  • Schneider Electric RM35S0MW Speed Control Relay 24-240Vac/Dc
  • Schneider Electric RM35S0MW Speed Control Relay 24-240Vac/Dc
  • Schneider Electric RM35S0MW Speed Control Relay 24-240Vac/Dc
$217.00

Description

This Harmony RM35-S control relay allows monitoring of speed control. This modular control relay is ideal for monitoring of electrical values and speed variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
View AllClose