Schneider Electric RM35S0MW Speed Control Relay 24-240Vac/Dc
Schneider Electric
$217.00
$1200 Minimum Order for Non-stock Items or $60 Addl Schneider Handling Fee Applies
This Harmony RM35-S control relay allows monitoring of speed control. This modular control relay is ideal for monitoring of electrical values and speed variation in industrial and building control panels. It applies to a wide type of industrial automation applications such as hoisting, packaging, lifts, textile, water. It has one of market medium form-factors with 35mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 3-pole DIN device. It also offers a selectable memory function, integral LED for indicating control status, sealable cover, with simple and precise settings with screw trimmers. It provides automatic shutdown management and fault information to user for a quick fault identification and troubleshooting. Multi function controller for wide choice selected in hard-wired logic automated systems, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
- Time Delay Type:
- adjustable 0.6...60 s Ti- inhibition time delay upon startup
- Measurement Error:
- +/- 0.1 %/°C with temperature variation || < +/- 1 % over the whole range with voltage variation
- Input Compatibility:
- 3-wire sensor (E1) PNP or NPN, 12 V, 50 mA || NAMUR sensor (E2), 12 V, 1.5 kOhm || voltage input (E1), 0...30 V, 9.5 kOhm >= 4.5 V <= 1 V || volt-free contact input (E1), 12 V, 9.5 kOhm
- China Rohs Regulation:
- X
- Product Certifications:
- C-tick || GOST || UL || GL || CSA
- Connections - Terminals:
- screw terminals, 1 x 0.5...1 x 4 mm² AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 12) flexible with cable end ||
- Polarity:
- reversible polarity on DC supply
- Rohs Exemption Information:
- Yes
- Minimum Switching Current:
- 10 mA 5 V DC
- Sustainable Offer Status:
- Green Premium product
- Repeat Accuracy:
- +/- 0.5 % input and measurement circuit || +/- 0.5 % time delay
- Status Led:
- 1 LED Green power ON || 1 LED Yellow inhibit || 1 LED Yellow relay (R)
- Maximum Switching Voltage:
- 250 V AC/DC
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Maximum Power Consumption In W:
- 3 W DC
- Overvoltage Category:
- III IEC 60664-1
- Electromagnetic Compatibility:
- emission standard for industrial environments IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments IEC 61000-6-3 || immunity for industrial environments NF EN/IEC 61000-6-2
- Housing Material:
- self-extinguishing plastic
- Product Or Component Type:
- speed control relay
- Dielectric Test Voltage:
- 2 kV AC 50 Hz
- Vibration Resistance:
- 0.35 mm 5-57.6 Hz)IEC 60068-2-6/IEC 60255-21-1 || 1 gn 57.6-150 Hz)IEC 60068-2-6/IEC 60255-21-1
- Relay Name:
- RM35S
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Time Delay Range:
- 0.6...60 s adjustable on energisation 0...10 % of the full scale value)
- Shock Resistance:
- 15 gn 11 ms IEC 60255-21-1
- Nominal Output Current:
- 0.208333333333333
- Supply Voltage Limits:
- 20.4-264 V AC/DC
- Circularity Profile:
- ENVEOLI1504008EN
- Marking:
- CE : EMC 89/336/EEC || CE : 73/23/EEC
- Pollution Degree:
- 3 IEC 60664-1
- Relative Humidity:
- 95-95 % 55-55 °C IEC 60068-2-30
- Relay Type:
- speed control relays
- Measurement Accuracy:
- +/- 10 % of the full scale value
- Mercury Free:
- Yes
- Mechanical Durability:
- 30000000 cycles
- Environmental Disclosure:
- ENVPEP1504008EN
- Tightening Torque:
- 0.6-1 N.m IEC 60947-1
- Eu Rohs Directive:
- Pro-active compliance (Product out of EU RoHS legal scope)
- Operating Rate:
- <= 360 operations/hour full load
- Electrical Durability:
- 100000 cycles
- Measurement Range:
- 0.05...0.5 s || 0.5...5 min || 1...10 min || 1...10 s || 0.5...5 s || 0.1...1 s || 0.1...1 min
- Switching Capacity In Va:
- 1250 VA
- Control Type:
- without test button
- Control Circuit Voltage Limits:
- 15 % + 10 % Un
- Supply Frequency:
- 50/60 Hz +/- 10 %
- Width:
- 35 mm
- [Ui] Rated Insulation Voltage:
- 250 V IEC 60664-1
- Utilisation Category:
- AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || DC-14 IEC 60947-5-1
- Hysteresis:
- 5-5 % threshold
- Mounting Support:
- 35 mm symmetrical DIN rail conforming to IEC 60715
- Ip Degree Of Protection:
- IP20 IEC 60529 terminals) || IP30 IEC 60529 casing)
- Run-Up Delay At Power-Up:
- 0.05 s
- Maximum Supply Current For Sensors:
- 40 mA < 24 V AC 25 °C || 40 mA < 24 V DC 25 °C || 50 mA 24...240 V AC || 50 mA 24...240 V DC
- Output Contacts:
- 1 C/O
- Ambient Air Temperature For Operation:
- -20-50 °C
- Maximum Power Consumption In Va:
- 5 VA AC
- Impulse Duration:
- >= 5 ms high state || >= 5 ms low state
- Warranty:
- 18 months
- Threshold Setting:
- 10...100 %
- Measurement Range:
- 0.05...600 s AC/DC
- Non-Dissipating Shock Wave:
- 4 kV
- Immunity To Microbreaks:
- 50 ms
- Range Of Product:
- Harmony Control Relays
- Standards:
- NF EN 60255-6 || IEC 60255-6
- Relay Monitored Parameters:
- overspeed || underspeed
- Weee:
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- Response Time:
- 15 ms max (on crossing the threshold)
- [Us] Rated Supply Voltage:
- 11.5...12.5 V
- Ambient Air Temperature For Storage:
- -40-70 °C
- Input Frequency:
- 0.0017-20 Hz
- Contacts Material:
- cadmium free
- Reset Time:
- 50 ms contact S2 in memory mode on time delay || 1 s supply Un in memory mode on time delay
- Operating Position:
- any position without derating
- Insulation Resistance:
- > 500 MOhm 500 V DC between supply and relay output IEC 60255-5 || > 500 MOhm 500 V DC between measurement and relay output IEC 60664-1 || > 1 MOhm 500 V DC between supply and measurement IEC 60255-5 || > 500 MOhm 500 V DC between supply and relay ou
- Catalog:
- View
- Datasheet:
- View