Schneider Electric TM3SAK6RG Safety Module For Plc Tm2Xx, 3 Functions

(No reviews yet) Write a Review
SKU:
TM3SAK6RG
UPC:
3606485393049
Condition:
New
Standards:
ISO 13849-1:2008 || ISO 13849-2:2012 || IEC 62061:2005 || IEC 61508:2010 || IEC 60947-5-1:2010 || IEC 61131-2:2007 || IEC 60204-1:2005 || IEC 60204-1:2009/A1 || IEC 61010-1:2010 || EN 50581:2012
Electromagnetic Compatibility:
electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fiel
Breaking Capacity:
4 A 24 V 50 ms DC-13 relay output
Associated Fuse Rating:
4 A gG or gL relay output IEC 60947-5-1 || 6 A fast blow relay output IEC 60947-5-1
Standards:
EN 1088/ISO 14119 || IEC 60947-5-1 || IEC 60947-1 || IEC 60204-1 || ISO 13850
Input Protection Type:
internal, electronic
Range Of Product:
Modicon TM3 Safety
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Minimum Output Current:
10 mA relay output
Ip Degree Of Protection:
IP20 terminals)IEC 60529
Width:
43.7 mm
Surge Withstand:
1 kV power lines (DC) differential mode IEC 61000-4-5 DC || 1 kV power lines (DC) common mode IEC 61000-4-5 DC
Local Signalling:
for user 8 LEDs (green/red)
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pvc Free:
Yes
Mechanical Robustness:
bumps 6 ms 300 shocks 25 gn) IEC 60068-2-27
Pollution Degree:
2
Resistance To Conducted Disturbances:
10 V 0.15...80 MHz IEC 61000-4-6
Function Of Module:
emergency stop monitoring 1-channel wiring || emergency stop monitoring 2-channel wiring || monitoring of a movable guard with 2 switches and automatic start || monitoring of a movable guard || multiple emergency stop monitoring 2-channel wiring || p
Number Of Safety Circuits:
3 NO relay instantaneous opening
Vibration Resistance:
+/- 3.5 mm 5-150 Hz)IEC 60068-2-6
Safety Reliability Data:
DC = 95 % ISO 13849-1 || PFHd = 5E-9 1/h IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A || PFHd = 30E-9 1/h IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A || MTTFd = 500 years ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A || MTTFd = 85 years
Maximum Cable Distance Between Devices:
30 m
Current Consumption:
100 mA 24 V DC external supply
Electromagnetic Emission:
radiated emissions 50 dBµV/m class A 24 V DC)30-230 Hz IEC 61131-3 || radiated emissions 57 dBµV/m class A 24 V DC)230-1000 Hz IEC 61131-3
Rohs Exemption Information:
Yes
[Uc] Control Circuit Voltage:
24 V DC
Ambient Air Temperature For Operation:
-10-55 °C horizontal installation
Maximum Response Time On Input Open:
40 ms
Synchronisation Time Between Inputs:
unlimited || 2 or 4 s depending of wiring configurable by software
Output Voltage:
10 V relay output
Breaking Capacity:
360 VA holding AC-15 B300 relay output || 3600 VA inrush AC-15 B300 relay output
Output Thermal Current:
6 A per relay relay output
Marking:
CSA || RCM || UL || EFUP 10 || CE || TÜV || EAC
Maximum Switching Voltage:
230 V AC-15 50 Hz relay instantaneous opening) || 24 V DC-13 relay instantaneous opening)
Product Or Component Type:
safety module
Safety Module Application:
for emergency stop, switch, sensing mat/edges or safety light curtain monitoring
[Uimp] Rated Impulse Withstand Voltage:
4 kV III IEC 60647-5-1
Device Short Name:
TM3SAK
Product Compatibility:
safety light curtains EN/IEC 61496-1 (type 4) || sensing mat/edges EN 1760-1
Ambient Air Temperature For Storage:
-25-70 °C
Resistance To Fast Transients:
3 kV power lines (DC) DC)IEC 61000-4-4 || 2 kV I/O linesIEC 61000-4-4
Mercury Free:
Yes
Power Consumption In W:
0.2 W 5 V DC || 3.6 W 24 V DC
Net Weight:
0.19 kg
[Us] Rated Supply Voltage:
24 V - 15...20 % DC
Depth:
73 mm
Relative Humidity:
10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
Shock Resistance:
15 gn 11 ms IEC 60068-2-27
Connections - Terminals:
captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34 || captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 || captive
Height:
94 mm
Output Type:
relay instantaneous opening, 3 NO, potential free
Product Certifications:
CSA 61010-2-201 (pending) || TÜV || CSA Haz Loc Class 1 Division 2 (pending) || EAC || RCM || UL 61010-2-201 || ANSI Haz Loc Class 1 Division 2 (pending)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Sustainable Offer Status:
Green Premium product
Circularity Profile:
ENVEOLI1403010EN
Resistance To Electrostatic Discharge:
8 kV in air IEC 61000-4-2 || 6 kV on contact IEC 61000-4-2
Environmental Disclosure:
ENVPEP1403010EN
Resistance To Magnetic Fields:
30 A/m 50/60 Hz IEC 61000-4-8
Storage Altitude:
0-3000 m
Electrical Connection:
spring terminal
Mounting Support:
top hat type TH35-7.5 rail IEC 60715 || top hat type TH35-15 rail IEC 60715 || wall mount using attached fasteners
China Rohs Regulation:
X
[Ui] Rated Insulation Voltage:
300 V 2)IEC 60647-5-1
[Ith] Conventional Free Air Thermal Current:
18 A
Resistance To Electromagnetic Fields:
10 V/m 80 MHz...1 GHz IEC 61000-4-3 || 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3 || 1 V/m 2 GHz...3 GHz IEC 61000-4-3
Safety Level:
can reach PL e/category 4 ISO 13849-1 2008 || can reach PL e/category 4 ISO 13849-2 2012 || can reach SILCL 3 IEC 62061 2005 || can reach SIL 3 IEC 61508 2010
Operating Altitude:
0...6561.68 ft (0...2000 m)
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
  • Schneider Electric TM3SAK6RG Safety Module For Plc Tm2Xx, 3 Functions
  • Schneider Electric TM3SAK6RG Safety Module For Plc Tm2Xx, 3 Functions
$521.25

Description

This TM3 safety expansion module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of PL e/Category 4 conforming to EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 62061. It has a module locking latch, 2 TM3 bus connectors designed to provide continuity of the link between connected modules, a symmetrical rail locking clip, display block for the module channels and diagnostics. It completes your Modicon M221, M241 or M251 PLC configuration with a dedicated safety I/O, without the need to use a complete safety controller. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has spring terminals for fast and reliable wiring of safety circuits.
View AllClose