[Ui] Rated Insulation Voltage:
690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Net Weight:
0.255 kg
Device Presentation:
power module connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
Maximum Horse Power Rating:
2 hp at 120 V AC 60 Hz for 1 phase motors || 5 hp at 240 V AC 60 Hz for 1 phase motors || 10 hp at 208 V AC 60 Hz for 3 phase motors || 10 hp at 240 V AC 60 Hz for 3 phase motors || 20 hp at 480 V AC 60 Hz for 3 phase motors || 25 hp at 600 V AC 60 H
Standards:
EN/IEC 60947-1 || EN/IEC 60947-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Protection Type:
thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase loss || rapid restart lockout || phase reversal || phase sequence || phase unbalance || ground current
Vibration Resistance:
1.5 mm peak to peak 3-13 Hz) IEC 60068-2-6 || 1 gn 13-200 Hz) IEC 60068-2-6
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Current Consumption:
60 mA
Product Or Component Type:
power module
Product Certifications:
EAC || CCC || CSA || UL
Environmental Disclosure:
ENVPEP1904009EN
Operating Altitude:
0...6561.68 ft (0...2000 m) without derating
Motor Power Kw:
9 kW at 230 V AC 50 Hz || 18.5 kW at 380...415 V AC 50 Hz || 18.5 kW at 440 V AC 50 Hz || 18.5 kW at 500 V AC 50 Hz || 18.5 kW at 690 V AC 50 Hz
Function Available:
upstream voltage presence detection || electronic thermal overload protection || monitoring of currents || control of third party power devices when associated to TPRDG IO module
Power Dissipation In W:
0.9 W at Ie AC-3
Poles Description:
3P
Protective Treatment:
TC
Thermal Overload Class:
class 5…30
Pollution Degree:
2
Eu Rohs Directive:
Compliant with Exemptions
Ambient Air Temperature For Storage:
-25-70°C
Fire Resistance:
960°C UL 94 || 850°C IEC 60695-2-1 || 650°C IEC 60695-2-12
[Uc] Control Circuit Voltage:
24 V DC supplied by the bus coupler
[Ue] Rated Operational Voltage:
<= 690 V AC 47...63 Hz
Height:
121 mm
Overvoltage Category:
III
Rohs Exemption Information:
Yes
Mercury Free:
Yes
Electromagnetic Compatibility:
electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 || radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 || fast transient immunity test, level 4, 4 kV, conforming to E
Tightening Torque:
2.5-2.5 N.m flat Ø 6 mm || 2.5-2.5 N.m Philips No 3
Circularity Profile:
ENVEOLI1904009EN
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Thermal Protection Adjustment Range:
0.76-38 A
Reset:
remotely or automatically
Country of Origin:
United States
Product Compatibility:
TPRBC bus coupler || TPRDG digital IO module || TPRAN analog IO module
Ip Degree Of Protection:
IP20
Local Signaling:
for DS (device status) 1 LED (green/red) || for LS (load status) 1 LED (green/red)
[Uimp] Rated Impulse Withstand Voltage:
6 kV
Shock Resistance:
15 gn 11 ms) IEC 60068-2-27
Sustainable Offer Status:
Green Premium product
Relative Humidity:
5-95 %
[Ie] Rated Operational Current:
38 A (at <50°C) at <= 440 V AC-3 || 40 A (at <50°C) at <= 440 V AC-1 || 40 A (at <50°C) AC-3e
Ambient Air Temperature For Operation:
-10-50°C without derating || 50-60°C with current derating
Product Name:
TeSys island
Depth:
115 mm
$250.00

Description

TeSys island power module, 3 poles, 38A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 38A and motors up to 18.5kW@400V / 20hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.76-38A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).