Schneider Electric

Schneider Electric TPRSS080 SIL motor starter, TeSys island, 80A at AC-1, 66A at AC-3, 37kW, 40hp, DOL type

(No reviews yet) Write a Review
SKU:
TPRSS080
MPN:
TPRSS080
Condition:
New
Motor Starter Type:
direct on line
Average Impedance:
1.5 mOhm - Ith 80 A 50 Hz
Mounting Mode:
horizontal and vertical 35 mm symmetrical DIN rail)
Tightening Torque:
5-5 N.m 1-25 mm² hexagonal 4 mm || 8-8 N.m 25-35 mm² hexagonal 4 mm
[Ith] Conventional Free Air Thermal Current:
80 A (at 50°C)
[Ie] Rated Operational Current:
66 A (at <50°C) at <= 440 V AC-3 || 80 A (at <50°C) at <= 440 V AC-1
Eu Rohs Directive:
Compliant with Exemptions
Net Weight:
1.248 kg
Connections - Terminals:
EverLink BTR screw connectors 1 1-35 mm² AWG 16...AWG 2)rigid || EverLink BTR screw connectors 2 1-25 mm² AWG 16...AWG 4)rigid || EverLink BTR screw connectors 1 1-35 mm² AWG 16...AWG 2)flexible without cable end || EverLink BTR screw connector
Device Presentation:
direct starter connected to an automation controller through a bus coupler || operational only when connected to a bus coupler
Local Signaling:
for DS (device status) 1 LED (green/red) || for LS (load status) 1 LED (green/red)
Operating Altitude:
0...6561.68 ft (0...2000 m) without derating
Overvoltage Category:
III
Power Dissipation Per Pole:
6.5 W AC-3 || 9.6 W AC-1
Thermal Protection Adjustment Range:
4-80 A
Mechanical Durability:
6 Mcycles
Country of Origin:
Mexico
Rated Breaking Capacity:
1000 A at 440 V conforming to IEC 60947
Utilisation Category:
AC-1 || AC-2 || AC-3 || AC-4 || AC-3e
[Uimp] Rated Impulse Withstand Voltage:
6 kV IEC 60947-1
Shock Resistance:
15 gn 11 ms) IEC 60068-2-27
Protective Treatment:
TC
Safety Level:
SIL 2 conforming to IEC 61508 in single channel system architecture || SILCL 2 conforming to IEC 62061 in single channel system architecture || PL = d category 2 conforming to ISO 13849-1 in single channel system architecture
Poles Description:
3P 3 NO
Reset:
remotely or automatically
Product Compatibility:
TPRBC bus coupler || TPRVM voltage interface module || TPRSM SIL interface module
Product Certifications:
CSA || CCC || UL || EAC
Current Consumption:
80 mA contactor sealed || 500 mA contactor closing
Ambient Air Temperature For Operation:
-10-50°C without derating || 50-60°C with current derating
Maximum Operating Rate:
3600 cyc/mn AC-3
Operating Time:
< 80 ms closing || < 80 ms opening
Thermal Overload Class:
class 5…30
Fire Resistance:
960°C UL 94 || 850°C IEC 60695-2-1 || 650°C IEC 60695-2-12
Product Name:
TeSys island
[Ui] Rated Insulation Voltage:
690 V IEC 60947-4-1 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Protection Type:
thermal overload protection || motor overheat || overcurrent || undercurrent || jam || long start || stall || rapid cycle lockout || phase sequence || rapid restart lockout || phase loss || phase reversal || phase unbalance || ground current
Function Available:
upstream voltage presence detection || electrical line and load protection || power and energy monitoring when connected with TPRVM voltage module || safe stop function available when connected with a TPRSM module
[Icw] Rated Short-Time Withstand Current:
900 A 40°C - 1 s || 520 A 40°C - 10 s || 260 A 40°C - 1 min || 110 A 40°C - 10 min
Environmental Disclosure:
ENVPEP1904009EN
Safety Function:
safe stop: category 0 conforming to IEC 60204-1 when associated with a TPRSM module || safe stop: category 1 conforming to IEC 60204-1 when associated with a TPRSM module
[Ue] Rated Operational Voltage:
<= 690 V AC 47...63 Hz
Irms Rated Making Capacity:
1000 A at 440 V conforming to IEC 60947
Safety Reliability Level:
B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 || B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Motor Power Kw:
18.5 kW at 230 V 50 Hz (AC-3) || 37 kW at 380...415 V 50 Hz (AC-3) || 37 kW at 440 V 50 Hz (AC-3) || 37 kW at 500 V 50 Hz (AC-3) || 37 kW at 690 V 50 Hz (AC-3)
Ip Degree Of Protection:
IP20
$765.00

Description

TeSys island direct SIL starter, 3 poles, 80A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 80A and motors up to 37kW@400V / 40hp@480V. In association with a TPRSM001 module and an external safety device, it can be used for safety related systems conforming to IEC 61508. It provides motor protection functions including thermal overload (setting 4-80A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
View AllClose