Schneider Electric XPSMCMEN0200TTG Speed Mon. 2 Ttl Exp. Spring Term

(No reviews yet) Write a Review
SKU:
XPSMCMEN0200TTG
UPC:
3606480748776
Condition:
New
Insulation:
250 V AC between power supply and housing IEC 61800-5-1
Local Signalling:
1 LED green PWR power ON || 1 LED green RUN RUN (status) || 1 LED red E IN internal error || 1 LED red E EX external error || 2 LEDs orange ADDR node address || 2 LEDs yellow PROX proximity sensors connection status || 2 LEDs yellow SH speed monitori
Height:
99 mm
Sensor Type:
inductive proximity sensor
China Rohs Regulation:
X
Depth:
22.5 mm
Product Or Component Type:
safe speed monitoring module
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Vibration Resistance:
+/-0.35 mm 10-55 Hz)IEC 61496-1
Sustainable Offer Status:
Green Premium product
Environmental Disclosure:
ENVPEP1409010EN
Integrated Connection Type:
backplane expansion bus
Rohs Exemption Information:
Yes
Quality Labels:
CE
Safety Level:
can reach category 4 ISO 13849-1 || can reach PL = e ISO 13849-1 || type 4 IEC 61496-1 || SILCL 3 IEC 62061
Discrete Input Voltage:
24 V DC
Connections - Terminals:
1 spring clamp terminals, removable terminal block || 2 spring clamp terminals, removable terminal block
Standards:
IEC 61496-1 || IEC 61800-5-1 || ISO 13849-1 || IEC 62061 || IEC 61508
Ambient Air Temperature For Storage:
-20-85 °C
Function Of Module:
speed monitoring
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Power Consumption In W:
3 W
Number Of Terminal Blocks:
4
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Circularity Profile:
ENVEOLI1409010EN
Overvoltage Category:
II
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Power Dissipation In W:
3 W
Device Short Name:
XPSMCM
Net Weight:
0.3 kg
Product Certifications:
TÜV || cULus || RCM
Electrical Connection:
spring terminal
Electrical Connection:
1 connector RJ45 EIA/TIA-568-A
[Uimp] Rated Impulse Withstand Voltage:
4 kV IEC 61800-5
Electromagnetic Compatibility:
electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fields - test lev
Relative Humidity:
10-95 %
Mounting Support:
omega 35 mm DIN rail EN 50022
Mercury Free:
Yes
Pollution Degree:
2
Ip Degree Of Protection:
IP20 enclosure)
Cable Cross Section:
0.2-2.5 mm² flexible without cable end || 0.2-2.5 mm² solid without cable end || 0.25-2.5 mm² flexible with cable end, with bezel || 0.25-2.5 mm² flexible with cable end, without bezel || 0.5-1 mm² flexible with cable end, with double bezel
Shock Resistance:
10 gn 16 ms) 1000 shocks on each axis IEC 61496-1
Width:
114.5 mm
Range Of Product:
Preventa Safety automation
Maximum Input Frequency:
5 kHz sensor || 500 kHz encoder TTL
Pvc Free:
Yes
Ambient Air Temperature For Operation:
-10-55 °C
[Us] Rated Supply Voltage:
24 V - 20...20 % DC
Service Life:
20 year(s)
Reach Free Of Svhc:
Yes
$2,139.75

Description

This Modicon MCM safe speed monitoring module has 2 TTL encoder inputs (with RJ45 connectors) and 2 proximity sensor inputs (connection via terminal) and is fitted with captive spring clamp terminals. It is designed to monitor zero speed control, max speed (limited speed), speed range and direction. It has a rated supply voltage of 24V DC. It offers up to four logically selectable limited speed thresholds (freely configurable via SoSafe Configurable software) for each logical intput (axis), and a maximum input frequency of 500kHz (for encoders) and 5kHz for proximity sensors. It completes your safety CPU with safe-speed monitoring function, ideal for cutting machines like band-saw, circular saw and grinding machines. This module figures LEDs on its front face, displaying the status (power supply, reset, internal or external errors, node address, encoder or proximity sensors connection status, speed monitoring status). The safe speed monitoring module is connected to the safety controller via the backplane expansion connector. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. This module can reach such safety levels as category 4 conforming to EN/ISO 13849-1, PL = e conforming to EN/ISO 13849-1, Type 4 conforming to EN/IEC 61496-1, and SILCL 3 conforming to IEC 62061. The modular safety controllers Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessories for Modicon MCM module are a memory card and the backplane connector. The safe speed monitoring module instals on Omega 35mm DIN rail conforming to EN 50022, and is connected to the safety controller via the backplane expansion connector. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
View AllClose