Safety Reliability Data:
B10d = 300000 AC-15 230 V, , <3 A ISO 13849-1 || B10d = 750000 AC-15 230 V, , <1 A ISO 13849-1 || B10d = 10000000 DC-13 24 V, , <2 A ISO 13849-1
Connections - Terminals:
2 captive screw clamp terminals, removable terminal block || 1 captive screw clamp terminals, removable terminal block
Mounting Support:
omega 35 mm DIN rail EN 50022
Electrical Durability:
20000000 cycles
Ip Degree Of Protection:
IP20
Pvc Free:
Yes
Switching Time:
12 ms
Ambient Air Temperature For Storage:
-20-85 °C
Quality Labels:
CE
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Electrical Connection:
screw terminal
Ambient Air Temperature For Operation:
-10-55 °C
Service Life:
20 year(s)
Local Signalling:
1 LED green PWR power ON || 1 LED green RUN RUN (status) || 1 LED red E IN internal error || 1 LED red E EX external error || 2 LEDs orange ADDR node address || 4 LEDs green/red RELAY K1...K4 relay contact || 4 LEDs yellow RST reset
Maximum Switching Current:
0.25
Vibration Resistance:
+/-0.35 mm 10-55 Hz)IEC 61496-1
Quantity Per Set:
1
Reach Free Of Svhc:
Yes
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Insulation:
250 V AC between power supply and housing IEC 61800-5-1
Height:
99 mm
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Net Weight:
0.3 kg
Product Or Component Type:
safe relay output module
Sustainable Offer Status:
Green Premium product
Switching Voltage:
10 V DC
Mechanical Durability:
20000000 cycles
Maximum Switching Voltage:
400 V AC || 250 V DC
Circularity Profile:
ENVEOLI1409010EN
Device Short Name:
XPSMCM
[Uimp] Rated Impulse Withstand Voltage:
4 kV IEC 61800-5-1
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Safety Level:
can reach category 4 ISO 13849-1 || can reach PL = e ISO 13849-1 || can reach SIL 3 IEC 61508 || SILCL 3 IEC 62061
Number Of Terminal Blocks:
4
Cable Cross Section:
0.2-1.5 mm² - AWG 24...AWG 16 flexible without cable end || 0.2-2.5 mm² - AWG 24...AWG 14 flexible without cable end || 0.25-1 mm² - AWG 23...AWG 18 flexible with cable end, without bezel || 0.25-2.5 mm² - AWG 23...AWG 14 flexible with cable end,
Depth:
114.5 mm
China Rohs Regulation:
X
[Us] Rated Supply Voltage:
24 V - 20...20 % DC
Shock Resistance:
10 gn 16 ms 1000 shocks on each axis)IEC 61496-1
Pollution Degree:
2
Maximum Power Dissipation In W:
3 W
Integrated Connection Type:
backplane expansion bus
Standards:
IEC 62061 || ISO 13849-1 || IEC 61800-5-1 || IEC 61508
Output Type:
relay, 4 NO, volt-free
Discrete Output Number:
8-8 solid state 125 mA diagnostics)
Minimum Switching Current:
20 mA
Mercury Free:
Yes
Overvoltage Category:
II
Relative Humidity:
10-95 %
Range Of Product:
Preventa Safety automation
Electromagnetic Compatibility:
electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to IEC 61000-4-2 || electrostatic discharge immunity test - test level: 20 kV (on air) conforming to IEC 61000-4-2 || susceptibility to electromagnetic fields - test lev
Width:
22.5 mm
Associated Fuse Rating:
3.5 A, slow-blow
Number Of Outputs:
4 relay
Environmental Disclosure:
ENVPEP1409010EN
Product Certifications:
TÜV || RCM || cULus
Function Of Module:
monitoring safety actuators relay output
Rohs Exemption Information:
Yes
Catalog:
View
Datasheet:
View
$659.00

Description

This Modicon MCM safe relay output expansion module has 4 start/restart interlock inputs, 4 relays and is fitted with captive screw clamp terminals. It is designed to monitor safety actuators for relay outputs, with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with screw clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The safe relay modules type XPSMCMER0004 use guided contact safety relays, each of which provides two N.O. contacts and one N.C. contact in addition to the N.C. feedback contact. This safe relay output expansion module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, restart signal, output channels). The safe relay output modules type XPSMCMER0002 and XPSMCMER0004 do not require the backplane expansion connectors as they are directly wired to the selected OSSD. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessory for safe relay output module is a memory card. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.