WAGO 750-672 Stepper Controller Module
Wago
$992.40
Stepper Controller; 70 VDC; 7.5 A
Technical Data
- Device-specific: Inputs (preset): DI 1: Drive stop, DI 2: Reference input, DI 3: Jog switch in positive direction, DI 4: Jog switch in negative direction, DI 5: Limit switch in positive direction, DI 6: Limit switch in negative direction, Outputs (preset): DO 1: Target reached, DO 2: Error, Inputs and outputs can be freely reconfigured.
- Number of digital outputs: 2
- No. of outputs: 1 stepper motor (2 phases)
- Input filter: 100 s, software filter can be installed
- Input current typ.: 2.8 mA
- Output current per channel: 0.5 A
- Output current: short-circuit-protected
- Switching frequency max.: 5 Hz; inductive load to IEC947-5-1, DC13
- Type of load: Resistive load, inductive load (max. 2H), lamps
- Motor current: 2 x 7.5 A temporary; derating starting at 50 C; 2 x 5.0 A nominal current; derating starting at 50 C
- Output voltage: <b>Control voltage</b>: 24 V DC (-25 % ... +30 %), Closed current 120 mA + 2 x 0.5 A (DO1, DO2, load-dependent); <b>Motor voltage</b>: Nominal value 55 V DC, Absolute upper limit: 71.5 V, Absolute lower limit: 18 V, Closed current typ. = 5 mA, Protection via external fuse 5 A
- Voltage range for signal (0): +5 VDC
- Voltage range for signal (1): 15 30 VDC
- Diagnostics: Overcurrent, short circuit or ground fault, overtemperature, supply voltage monitoring, motor wire break
- Resolution: 15 bits + 16 bit prescaler; 64 microsteps per full step
- Resolution Stepper: 23 bits + sign bit
- Load type of the switching frequency: inductive load to IEC947-5-1, DC13
- Schrittfrequenz, Vollschritt max: 7812 Hz
- Bit width: 12 byte inputs/outputs
- Protection: Short circuit monitoring of motor connections: Winding short circuit and short circuit to 0 V and 24 V; 24 V supply: Reverse voltage protection; Motor supply: Reverse voltage protection via external fuse
- Functions: Positioning, sin-shaped ramps, setpoint change on the fly, rotational speed control
- System supply voltage: DC 5 V; via data contacts
- Current consumption, system supply (5 V): 70 mA
- Isolation: 500 V system/supply
Connection Data
- Connection technology: In-/Outputs: 24 x CAGE CLAMP<sup></sup>
- Connection type (1): Inputs/Outputs
- Solid conductor: 0.08 1.5 mm / 28 14 AWG
- Fine-stranded conductor: 0.08 1.5 mm / 28 14 AWG
- Strip length: 5 6 mm / 0.2 0.24 inch
- Anschlussanforderung zul¤ssige Leitungsl¤nge: 30 m
- Connection requirement (permissible cable type): Motoranschluss: geschirmt
- Note (conductor cross-section): 14 AWG: THHN, THWN
Geometrical Data
- Width: 48 mm / 1.89 inch
- Height: 69.8 mm / 2.748 inch
- Height from upper-edge of DIN-35 rail: 62.6 mm / 2.465 inch
- Depth: 100 mm / 3.937 inch
Mechanical Data
- Type of mounting: DIN-35 rail
Material Data
- Color: light gray
- Housing material: Polycarbonate, polyamide 6.6
- Fire load: 0.000 MJ
- Weight: 175.000 g
- Conformity marking: CE
Environmental Requirements
- Surrounding air (operating) temperature: 0 55 C
- Surrounding air (storage) temperature: -40 85 C
- Protection class: IP20
- Degree of pollution (5): 2 per IEC 61131-2
- Operating altitude: 0 2000 m
- Mounting position: horizontal (standing/lying) or vertical
- Relative air humidity (no condensation): 95 %
- Vibration resistance: acc. to IEC 60068-2-6
- Shock resistance: 15g per IEC 60068-2-27
- EMC immunity to interference: acc. to EN 61000-6-2
- EMC emission of interference: acc. to EN 61000-6-3
- Exposure to pollutants: Per IEC 60068-2-42 and IEC 60068-2-43
- Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 %: 10 ppm
- Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 %: 25 ppm
Commercial data
- Packaging type: BOX
- Country of origin: DE
- GTIN: 4045454763701
- Customs Tariff No.: 85389091890
The WAGO 750 series Stepper Motor Controller is designed for use with a 55V DC motor supply output and features a 70V DC, 7.5A stepper controller. It operates with a 5V DC supply voltage provided by the system and includes Push-in spring CAGE CLAMP connections for secure wiring. The unit is mounted on a DIN-35 rail with a 12mm width and has an IP20 protection rating. It is suitable for ambient temperatures ranging from 0°C to +55°C and is equivalent to model 750672.
- Color:
- Light Gray
- conformity marking:
- CE
- connection requirement permissible cable length:
- 30 m
- connection requirement permissible cable type:
- Motor connection: shielded
- connection technology inputs outputs:
- 24 x CAGE CLAMP
- connection type 1:
- Inputs/outputs
- country of origin sales organisation germany:
- DE
- data width:
- 12-byte input/output
- depth:
- 69.8 mm / 2.748 inch
- depth from upper edge of din rail:
- 62.6 mm / 2.465 inch
- device specific:
- Inputs (preset): DI 1: Drive stop, DI 2: Reference input, DI 3: Jog switch in positive direction, DI 4: Jog switch in negative direction, DI 5: Limit switch in positive direction, DI 6: Limit switch in negative direction, Outputs (preset): DO 1: Targ
- diagnostics:
- Overcurrent, short circuit or ground fault, overtemperature, supply voltage monitoring, motor wire break
- emc emission of interference:
- Per EN 61000-6-3
- emc immunity to interference:
- Per EN 61000-6-2
- exposure to pollutants:
- Per IEC 60068-2-42 and IEC 60068-2-43
- fine stranded conductor:
- 0.08 1.5 mm / 28 14 AWG
- fire load:
- 2.382 MJ
- full step stepper frequency max:
- 7812 Hz
- Positioning, sin-shaped ramps, setpoint change on the fly, rotational speed controlheight:
- 100 mm / 3.937 inch
- housing material:
- Polycarbonate: polyamide 6.6
- input current typ:
- 2.8 mA
- input filter:
- 100 s, software filter can be connected
- isolation:
- 500 V system/field
- load type:
- Resistive load, inductive load (max. 2 H), lamps
- load type of switching frequency:
- Inductive load per IEC 947-5-1, DC 13
- mounting position:
- Horizontal (standing/lying): vertical
- mounting type:
- DIN-35 rail
- note conductor cross section:
- 14 AWG: THHN, THWN
- number of digital outputs:
- 2
- number of outputs:
- 1 stepper motor (2 phases)
- operating altitude:
- 0 2000 m
- output current:
- Short-circuit-protected
- output current max motor:
- 2 x 5.0 A (2 x 7.5 A transient)
- output current per channel:
- 0.5 A
- output voltage:
- Control voltage: 24 VDC (-25 % +30 %), Closed current 120 mA + 2 x 0.5 A (DO1, DO2, load-dependent) Motor voltage: Nominal value 55 VDC, Absolute upper limit: 71.5 V, Absolute lower limit: 18 V, Closed current typ. = 5 mA, Protection via extern
- packaging type:
- Box
- permissible h2s contaminant concentration at a relative humidity 75:
- 10 ppm
- permissible so2 contaminant concentration at a relative humidity 75:
- 25 ppm
- pollution degree 5:
- 2 per IEC 61131-2
- power consumption 5 v system supply:
- 70 mA
- protection:
- Short circuit monitoring of motor connections: Winding short circuit and short circuit to 0 V and 24 V 24 V supply: Reverse voltage protection Motor supply: Reverse voltage protection via external fuse
- protection type:
- IP20
- relative humidity without condensation:
- 0.95
- resolution:
- 15 bits + 16 bit prescaler: 64 microsteps per full step
- shock resistance:
- 15g per IEC 60068-2-27
- solid conductor:
- 0.08 1.5 mm / 28 14 AWG
- stepper resolution:
- 23 bits + sign bit
- strip length:
- 5 6 mm / 0.2 0.24 inch
- supply voltage system:
- 5 VDC: via data contacts
- surrounding air temperature operation:
- 0 55 C
- surrounding air temperature storage:
- -40 85 C
- switching frequency max:
- 5 Hz: Inductive load per IEC 947-5-1, DC 13
- vibration resistance:
- Per IEC 60068-2-6
- voltage range for signal 0:
- 3 +5 VDC
- voltage range for signal 1:
- 15 30 VDC
- weight:
- 175.000 g
- width:
- 48 mm / 1.89 inch