Schneider Electric 8502SBO1V02S NEMA Contactor, Type S, nonreversing, Size 0, 18A, 2HP at 230VAC, 1 phase, up to 100kA, 2 pole, 120VAC coil, open
Schneider Electric
$372.00
Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 0 non-reversing contactor has an 18 ampere rating. Single phase NEMA Size 0 contactors have 1 HP at 115 VAC and 2 HP at 230 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 110/120 VAC 50/60 Hz coil that is wired for separate control. This NEMA contactor is an open device without an enclosure. This contactor is 4.34 inches tall, 3.22 inches wide and 4.22 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.
- Rated Power In Hp:
- 1 HP 115 V AC || 2 HP 230 V AC
- Auxiliary Contact Composition:
- without
- Contactor Application:
- non-reversing
- Warranty:
- 18 months
- Control Type:
- no control units
- Product Or Component Type:
- contactor
- Depth:
- 107.19 mm
- Poles Description:
- 2P
- Product Compatibility:
- circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC || fuse J 60 A maximum, SCCR: 100 kA at 600 V AC || fuse T 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 60 A maximum, SCCR: 100 kA at 600
- [Ue] Rated Operational Voltage:
- 600 V AC
- [Uc] Control Circuit Voltage:
- 120 V AC 60 Hz || 110 V AC 50 Hz
- Country of Origin:
- United States
- Product Certifications:
- UL listed file E78351 CCN NLDX || CSA
- China Rohs Regulation:
- Product out of China RoHS scope. Substance declaration for your information.
- Provided Equipment:
- fuse not supplied
- Nema Degree Of Protection:
- not rated (open device)
- California Proposition 65:
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive:
- Not compliant
- Line Rated Current:
- 18 A
- Electrical Connection:
- screw clamp terminals
- Range Of Product:
- 8502S
- Reach Regulation:
- Reference contains Substances of Very High Concern above the threshold
- Nema Size:
- 0
- Control Circuit:
- separate control circuit
- Phase:
- 1 phase
- Local Signaling:
- no indicator