10...20 ms coil de-energisation and NO opening || 10...20 ms coil energisation and NO closing || 15...25 ms coil de-energisation and NC closing || 5...15 ms coil energisation and NC opening
Control Circuit Type:
AC 50/60 Hz
Minimum Switching Current:
5 mA
Eu Rohs Directive:
Compliant
Mechanical Durability:
10 Mcycles
Inrush Power In Va:
30-30 VA (at 20°C)
Reach Free Of Svhc:
Yes
Operating Altitude:
6561.68 ft (2000 m) without derating
Environmental Disclosure:
ENVPEP1503003EN
Irms Rated Making Capacity:
110 A IEC 60947
Circularity Profile:
ENVEOLI1503003EN
Protective Treatment:
TC IEC 60068
Rohs Exemption Information:
Yes
Toxic Heavy Metal Free:
Yes
Flame Retardance:
V1 conforming to UL 94 || requirement 2 conforming to NF F 16-101 || requirement 2 conforming to NF F 16-102
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Utilisation Category:
AC-15 || DC-13
Range:
TeSys
Minimum Switching Voltage:
17 V
Reach Regulation:
Free of Substances of Very High Concern above the threshold
[Uc] Control Circuit Voltage:
400...415 V AC 50/60 Hz
Sustainable Offer Status:
Green Premium product
Contactor Application:
control circuit
Ip Degree Of Protection:
IP2X
Device Short Name:
CA2K
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Pole Contact Composition:
2 NO + 2 NC
Depth:
57 mm
Product Or Component Type:
control relay
Product Name:
TeSys CAK
Mounting Support:
rail || plate
Mercury Free:
Yes
Non Overlap Distance:
0.5 mm
Associated Fuse Rating:
10 A gG conforming to IEC 60947 || 10 A gG conforming to VDE 0660
Mechanical Robustness:
vibrations contactor open2 Gn, 5...300 Hz IEC 60068-2-6 || vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 || shocks contactor open10 Gn for 11 ms IEC 60068-2-27 || shocks contactor closed15 Gn for 11 ms IEC 60068-2-27
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 230-240V 50/60Hz AC control circuit, connection by screw clamp terminals. For...
TeSys K control relay, 4 contacts (2NO + 2NC), 10A/690V, for control of electromagnetic loads AC-15/DC-13. It provides a 220-230V 50/60Hz AC control circuit, connection by screw clamp terminals. For...