Schneider Electric

Schneider Electric CR1F400F7 TeSys F magnetic latching contactor - 3P(3 NO) - 400 A - 110 V AC/DC coil

(No reviews yet) Write a Review
SKU:
CR1F400F7
MPN:
CR1F400F7
Condition:
New
[Ie] Rated Operational Current:
400 A (at <40°C) at <= 440 V AC AC-3 || 500 A (at <40°C) at <= 440 V AC AC-1 || 370 A (at <40°C) at <= 440 V AC AC-4
Utilisation Category:
AC-1 || AC-3 || AC-4
Connections - Terminals:
lugs-ring terminals 2 150-150 mm² || bars 2 30 x 5 mm || power circuit bolted connection
Average Coil Consumption:
1600 VA AC 50...400 Hz latching || 16 VA AC 50...400 Hz unlatching || 1600 VA DC latching || 16 VA DC unlatching
Average Impedance:
0.28 mOhm - Ith 500 A 50 Hz
Range:
TeSys
Tightening Torque:
35 N.m
[Ui] Rated Insulation Voltage:
1000 V IEC 60158-1 || 1000 V IEC 60947-4 || 1000 V BS 775 || 1500 V VDE 0110 group C
Associated Fuse Rating:
400 A aM at <= 440 V || 500 A BS88 at <= 440 V || 500 A gG at <= 440 V
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Sustainable Offer Status:
Green Premium product
Product Name:
TeSys F
Rohs Exemption Information:
Yes
Country of Origin:
Czechia
Motor Power Kw:
200 kW at 400 V AC 50/60 Hz (AC-4)
Operating Altitude:
9842.52 ft (3000 m) without derating
Ambient Air Temperature For Operation:
-15-70°C
Mechanical Durability:
1 Mcycles
[Ue] Rated Operational Voltage:
1000 V AC 25...200 Hz
Eu Rohs Directive:
Compliant with Exemptions
Circularity Profile:
ENVEOLI1505009EN
Control Circuit Type:
AC 50...400 Hz || DC standard
Device Short Name:
CR1F
Operating Time:
40...75 ms latching || 50...100 ms unlatching
Pole Contact Composition:
3 NO
Environmental Disclosure:
ENVPEP1505009EN
Warranty:
18 months
Mercury Free:
Yes
[Uc] Control Circuit Voltage:
110 V AC 50...400 Hz || 110 V DC
Poles Description:
3P
Device Application:
control
Standards:
EN/IEC 60947-1 || EN/IEC 60947-4-1 || JIS C8201-4-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1
Protective Treatment:
TC
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Power Dissipation Per Pole:
45 W AC-3 || 70 W AC-1
Net Weight:
9.1 kg
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Control Circuit Voltage Limits:
latching: 0.85...1.1 Uc || unlatching: 0.85...1.1 Uc
[Icw] Rated Short-Time Withstand Current:
3600 A 40°C - 1 s || 3600 A 40°C - 5 s || 3600 A 40°C - 10 s || 2400 A 40°C - 30 s || 1700 A 40°C - 1 min || 1200 A 40°C - 3 min || 1000 A 40°C - 10 min
Product Certifications:
CB Scheme || UL || CSA || EAC || CE || UKCA
Contactor Application:
resistive load || motor control
California Proposition 65:
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Maximum Operating Rate:
120 cyc/h 40°C
Ambient Air Temperature For Storage:
-60-80°C
Depth:
219 mm
Rated Breaking Capacity:
4000 A at 220...440 V || 3500 A at 500 V || 1200 A at 1000 V || 3000 A at 660/690 V
$3,325.50

Description

TeSys F magnetic latching contactor, 3 poles (3NO), 400A/1000V AC-3, for motor applications up to 200kW@400V. It provides a double coil 110V AC (50-400Hz) or DC for latching and unlatching, bolt terminals for bars or cables with lugs. Supply to the coils must be applied by pulsed contacts leading to energy saving and no sensibility to interferences for contactors remaining in closed state for long periods. For operating rates until 120 cycles/hour and environments until 70°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks (instantaneous and time delay auxiliary contacts, suppressor blocks) and connection accessories (to be ordered separately). It conforms to IEC 60158-1 and IEC 60947-4, Green Premium product (RoHS/REACh).
View AllClose