Schneider Electric

Schneider Electric EDB34090AABASA Mini circuit breaker, E-Frame, 90A, 3 pole, 480Y/277VAC, 25kA max, bolt on, aux switch, alarm switch, shunt trip

(No reviews yet) Write a Review
SKU:
EDB34090AABASA
MPN:
EDB34090AABASA
Condition:
New
Eu Rohs Directive:
Compliant with Exemptions
Range Of Product:
125 A Frame EDB-EGB-EJB
Net Weight:
4 lb(US)
Country of Origin:
Mexico
Number Of Poles:
3
Mercury Free:
Yes
Number Of Spaces:
4
Trip Unit Rating:
2300-2300 A
Product Certifications:
cULus
Holding Current:
1000 A
Breaking Capacity:
18 kA 277 V AC || 25 kA 240 V AC || 18 kA 480Y/277 V AC || 25 kA 120 V AC || 25 kA 120/240 V AC
Rohs Exemption Information:
Yes
Circuit Breaker Application:
HACR rated
Breaking Capacity Code:
D
Trip Unit Technology:
thermal-magnetic
Product Destination:
NF panelboard
Device Short Name:
EDB
Device Composition:
shunt trip || alarm switch || auxiliary switch
Number Of Spaces Required:
4
Line Rated Current:
90 A
Depth:
4.05 in
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Electrical Connection:
lugs aluminium
Mounting Mode:
bolt-on
Warranty:
18 months
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Weight:
4 lb(US)
[Ue] Rated Operational Voltage:
480Y/277 V AC
Local Signaling:
trip indicator
Module Type:
E-Frame
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Product Or Component Type:
miniature circuit-breaker
Ambient Air Temperature For Operation:
40°C
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Protection Type:
overload || short-circuit
$1,978.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 90A, 3 pole, and has an operating voltage of 480Y/277 VAC. It also provides a 25 kA max interrupt rating at 120 VAC. This device has a hold current of 1000A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 2300A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This one includes an auxiliary switch, alarm switch and a shunt trip. This breaker was calibrated for 40 degrees C. HACR rated.
View AllClose