Schneider Electric

Schneider Electric EJB16050 Mini circuit breaker, E-Frame, 50A, 1 pole, 600Y/347VAC, 100kA max, bolt on

(No reviews yet) Write a Review
SKU:
EJB16050
MPN:
EJB16050
Condition:
New
[Ue] Rated Operational Voltage:
600Y/347 V AC
Device Short Name:
EJB
Mounting Mode:
bolt-on
Circuit Breaker Application:
HACR rated
China Rohs Regulation:
Product out of China RoHS scope. Substance declaration for your information.
Awg Gauge:
AWG 12...AWG 2/0 aluminium || AWG 14...AWG 2/0 copper
Weight:
2 lb(US)
Breaking Capacity Code:
J
Electrical Connection:
lugs aluminium
Trip Unit Technology:
thermal-magnetic
Product Destination:
NF panelboard
Number Of Poles:
1
Range Of Product:
125 A Frame EDB-EGB-EJB
Protection Type:
overload || short-circuit
Product Certifications:
cULus
Mercury Free:
Yes
Line Rated Current:
50 A
Eu Rohs Directive:
Pro-active compliance (Product out of EU RoHS legal scope)
Ambient Air Temperature For Operation:
40°C
Depth:
4.05 in
Holding Current:
630 A
Country of Origin:
Mexico
Product Or Component Type:
circuit-breaker
Module Type:
E-Frame
Net Weight:
2 lb(US)
Reach Regulation:
Reference contains Substances of Very High Concern above the threshold
Tightening Torque:
3.9-3.9 N.m 2.5-6 mm² (AWG 14...AWG 10) || 5.6-5.6 N.m 10-70 mm² (AWG 8...AWG 2/0)
Rohs Exemption Information:
Yes
Number Of Spaces:
1
Local Signaling:
trip indicator
Warranty:
18 months
Number Of Spaces Required:
1
Breaking Capacity:
25 kA 600Y/347 V AC
Trip Unit Rating:
1800-1800 A
$408.00

Description

E-Frame Breaker are Lighting Panelboard Circuit breakers that are proven effective and reliable which provide a wide variety or robust features that are use specifically in Square D NF Panelboards. This range of breaker is ideally designed to offer superior overload and short circuit protection. All E-Frame breakers have a thermal-magnetic trip unit as well as signal indicator that will indicate when a trip has occur. Mounting bolts are used to hold these breakers in place. This E-Frame breaker is 50A, 1 pole, and has an operating voltage of 600Y/347 VAC. It also provides a 100 kA max interrupt rating at 120 VAC. This device has a hold current of 630A which is the maximum current the breaker can be held to ensure it will trip and a trip current of 1800A which is the current value when the breaker is guaranteed to trip. Many accessories are available for this breaker. This breaker was calibrated for 40 degrees C. This product is UL Listed as High Intensity Discharge. HACR rated.
View AllClose