Schneider Electric

Schneider Electric GB2CB08 TeSys GB2 thermal magnetic circuit protector, 1 P, 3 A, Id = 40 A

(No reviews yet) Write a Review
SKU:
GB2CB08
MPN:
GB2CB08
Condition:
New
Circularity Profile:
N/A
Mechanical Durability:
8000 cycles
Reach Regulation:
Free of Substances of Very High Concern above the threshold
Warranty:
18 months
Operating Altitude:
9842.52 ft (3000 m)
Tightening Torque:
1.2 N.m connector
Quantity Per Set:
set of 6
Electrical Durability:
8000 cycles
Ip Degree Of Protection:
IP20 IEC 60529
Network Type:
AC/DC
Connections - Terminals:
connector 1 0.75-6 mm²solid without cable end || connector 2 0.75-4 mm²solid without cable end || connector 1 0.75-4 mm²flexible with cable end || connector 2 0.75-2.5 mm²flexible with cable end
Mounting Mode:
by clips
Device Short Name:
GB2
Product Or Component Type:
circuit breaker
Weee:
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
Device Application:
control
China Rohs Regulation:
Pro-active China RoHS declaration (out of China RoHS legal scope)
Sustainable Offer Status:
Green Premium product
Protective Treatment:
TC
Mercury Free:
Yes
[Uimp] Rated Impulse Withstand Voltage:
4 kV IEC 60947-2
[Ics] Rated Service Short-Circuit Breaking Capacity:
50 % 110 V AC 50/60 Hz IEC 60947-2 || 50 % 230/240 V AC 50/60 Hz IEC 60947-2
Ambient Air Temperature For Storage:
-40-80°C
California Proposition 65:
WARNING: Cancer - www.P65Warnings.ca.gov
Ambient Air Temperature For Operation:
-20-60°C
Mechanical Robustness:
shocks 22 Gn for 20 ms IEC 60068-2-27 || vibrations 5 Gn, 5...110 Hz IEC 60068-2-6
Network Frequency:
50/60 Hz IEC 60947-2
Control Type:
toggle
Power Dissipation Per Pole:
2 W
Reach Free Of Svhc:
Yes
Mounting Support:
plate || rail
Product Certifications:
UL || CSA
Magnetic Tripping Current:
40-40 A
Environmental Disclosure:
ENVPEP2306023
Country of Origin:
China
Poles Description:
1P
[Ue] Rated Operational Voltage:
250 V AC 50/60 Hz IEC 60947-2 || 277 V AC 60 Hz CSA C22.2 No 235 || 277 V AC 60 Hz UL 1077 || 48 V DC
Standards:
EN/IEC 60947-1 || EN/IEC 60947-2 || CSA C22.2 No 235 || UL 1077
Mounting Position:
vertical || horizontal
Depth:
67 mm
Utilisation Category:
category A IEC 60947-2 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1
Breaking Capacity:
10 kA Icu 110 V AC 50/60 Hz IEC 60947-2 || 3 kA Icu 230/240 V AC 50/60 Hz IEC 60947-2 || 1.5 kA Icu 24 V DC IEC 60947-2 || 1 kA Icu 48 V DC IEC 60947-2
Range:
TeSys
9 Mm Pitches:
2
Eu Rohs Directive:
Compliant
Fire Resistance:
960°C IEC 60695-2-1
$43.60

Description

TeSys GB circuit breaker, 1 pole (1P), 3A/250V IEC/277V UL, for the protection of industrial equipment control circuits. It provides thermal-magnetic protection with a magnetic tripping level at 40A (13 In) and breaking capacity Icu 3kA@240V. It can also be used for protection of DC loads up to 3A/48V DC-13 with a breaking capacity Icu 1.5kA@24V. Compact device (15mm wide), mounting on 35mm DIN-rail, control by toggle lever (start-stop guaranteed for 8000 cycles). Sold in lots of 6 units. Multi standards certified (IEC, UL, CSA), Green Premium product (RoHS/REACh).
View AllClose